Dey 2019

Determining the Effectiveness of the Ventilation System in an Anatomy Lab using ISO 16000-8

  • Mohammadjavad Jafari
  • Manoochehr Mehrian
  • Mansuor Rezazadeh-Azari
  • Soheila Khodakarim

Irtiqa Imini Pishgiri Masdumiyat (Safety Promotion and Injury Prevention), Vol. 6 No. 3 (2018), 5 Dey 2019 , Page 122 - 113
https://doi.org/10.22037/meipm.v6i3.23924 Published: 2019-01-05

  • View Article
  • Download
  • Cite
  • References
  • Statastics
  • Share

Abstract

Background and Objectives: Dissection laboratories should have effective ventilation always. This study aimed to determine the effectiveness of the ventilation system in a dissection labratory.

Materials and Methods: Based on ISO 16000-8 using tracer gas decay method, the effectiveness of a ventilation system operating at 4 different modes including 1)exhaust system is “on”, 2) supply system is “on”, 3) both systems are “on”, and 4 both systems are “off” in a dissection lab was evaluated. Tracer gas (SF6) was injected into dissection lab and air sampling was conducted in five zones of the lab. The air samples were then transferred to the laboratory and their concentration was determined. Finally, the Local mean age (LMA) and Room mean age of air (RMA) and the rate of local and general exhaust ventilation were calculated. Ethical issues relatet to human bodies was considered in the research protochol.

Results: Two-way analysis of variances showed that while the LMA and the local rate of ventilation at different ventilating modes had no significant, the effect of ventilating mode on the RMA and general ventilation rate, was significant (P <0.001). One-way ANOVA test showed that the exhaust system had the greatest effect on RMA and general ventilation rate of the room.

Conclusion: According to the results, the ventilation is more effective when the supply and exhaust systems are “on” together considering the toxicity of formaldehyde, in addition to the general exhaust ventilation, the implementation of a local exhaust ventilation system for each mortuary desk is recommended.

How to cite this article: Jafari MJ, Mehrian M, Rezazadeh-Azari M, Khodakarim S. Determining the Effectiveness of the Ventilation System in an Anatomy Lab using ISO 16000-8.Irtiqa Imini Pishgiri Masdumiyat (Safety Promotion and Injury Prevention). 2018; 6(3):113-122.

Keywords:
  • ventilation effectiveness, local average age of air (LMA), tracer gas, ventilation rate
  • PDF (فارسی)

How to Cite

1.
Jafari M, Mehrian M, Rezazadeh-Azari M, Khodakarim S. Determining the Effectiveness of the Ventilation System in an Anatomy Lab using ISO 16000-8. Irtiqa Imini Pishgiri Masdumiyat [Internet]. 2019 Jan. 5 [cited 2026 Jul. 25];6(3):122-13. Available from: https://journals.sbmu.ac.ir/spip/article/view/23924
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX

References

Han H, Shin C-Y, Lee I-B, Kwon K-S. Tracer gas experiment for local mean ages of air from individual supply inlets in a space with multiple inlets. Building and Environment. 2011;46(12): 2462-71. [Scopus]

Wang A, Zhang Y, Sun Y, Wang X. Experimental study of ventilation effectiveness and air velocity distribution in an aircraft cabin mockup. Building and Environment. 2008;43(3):337-43. [Scopus]

Roos A. On the effectiveness of ventilation: Technische Universiteit Eindhoven, Faculteit Bouwkunde; 1999.

Occupational Safety Health Administration. Formaldehyde fact sheet. 2002. US Department of labor.

Rosen JC. Assessing Formaldehyde Exposure in Your Gross Lab:Occupational Exposure Limits and Best Practices. The FASEB Journal. 2012; 26 (1_Meeting Abstracts): 340.2..

Cogliano VJ, Grosse Y, Baan RA, Straif K, Secretan MB, El Ghissassi F, et al. Meeting report: summary of IARC monographs on formaldehyde, 2-butoxyethanol, and 1-tert-butoxy-2-propanol. Environmental health perspectives. 2005:1205-8. [PubMed]

International Agency for Research on Cancer(IARC). Monographs on the Evaluation of Carcinogenic Risks to Humans:Formaldehyde,2-Butoxyetha-nol and 1-tert-Butoxy-2-propanol,8thIAfRoC.Volume88:2–9 (June).www.cie.iarc.fr/htdocs/announcements/vol88.html.2004.

Tang X, Bai Y, Duong A, Smith MT, Li L, Zhang L. Formaldehyde in China: Production, consumption, exposure levels, and health effects. Environment international. 2009; 35(8): 1210-24. [Scopus]

Coleman R, Kogan I. An improved low‐formaldehyde embalming fluid to preserve cadavers for anatomy teaching. Journal of anatomy. 1998;192(3):443-6. [PubMed]

Kawamata S, Kodera H. Reduction of formaldehyde concentrations in the air and cadaveric tissues by ammonium carbonate. Anatomical science international. 2004; 79(3): 152-7. [Scopus]

De la Torre FR, Baeza AR, Mateu JMD. Seetting up a plastination laboratory at the Faculty of medicine of Autonomous University of Barcelona. European Journal of anatomy. 2004;8(1):1-6.

Al-Hayani AA, Hamdy RM, Abd El-Aziz GS, Badawoud MH, Aldaqal S, Bedir Y. Shellac. A non-toxic preservative for human embalming techniques. Journal of Animal and Veterinary Advances. 2011; 10(12): 1561-7. [Scopus]

Azari MR, Asadi P, Jafari MJ, Soori H, Hosseini V. Occupational Exposure of a Medical School Staff to Formaldehyde in Tehran. Tanaffos. 2012; 11(3): 36. [Scopus]

Yamato H, Nakashima T, Kikuta A, Kunugita N, Arashidani K, Nagafuchi Y, et al. A novel local ventilation system to reduce the levels of formaldehyde exposure during a gross anatomy dissection course and its evaluation using real-time monitoring. Journal of occupational health. 2005; 47(5): 450-3. [Scopus]

Ohmichi K, Komiyama M, Matsuno Y, Takanashi Y, Miyamoto H, Kadota T, et al. Formaldehyde exposure in a gross anatomy laboratory. Personal exposure level is higher than indoor concentration (5 pp). Environmental Science and Pollution Research. 2006; 13(2): 120-4. [Scopus]

Keil CB, Akbar-Khanzadeh F, Konecny KA. Characterizing formaldehyde emission rates in a gross anatomy laboratory. Applied occupational and environmental hygiene. 2001; 16(10): 967-72. [Scopus]

Demer FR. Effective Local Exhaust Ventilation for Controlling Formaldehyde Exposures in a Gross Anatomy Laboratory. 1996. Departments of Risk Management & Safety and Facilities Design & Construction"The University of Arizona, Tucson, Arizona, 85721

Nacher V, Llombart C, Carretero A, Navarro M, Ysern P, Calero S, et al. A new system to reduce formaldehyde levels improves safety conditions during gross veterinary anatomy learning. Journal of veterinary medical education. 2007; 34(2): 168-71. [Scopus]

Hiipakka DW, Dyrdahl KS, Cardenas MG. Successful reduction of morticians' exposure to formaldehyde during embalming procedures. AIHAJ-American Industrial Hygiene Association. 2001;62(6):689-96. [Scopus]

Chia SE, Ong CN, Foo SC, Lee HP. Medical students' exposure to formaldehyde in a gross anatomy dissection laboratory. Journal of American College Health. 1992;41(3):115-9. [Scopus]

Perkins JL, Kimbrough JD. Formaldehyde exposure in a gross anatomy laboratory. Journal of Occupational and Environmental Medicine. 1985;27(11):813-4. [Scopus]

Ye X, Yan W, Xie H, Zhao M, Ying C. Cytogenetic analysis of nasal mucosa cells and lymphocytes from high-level long-term formaldehyde exposed workers and low-level short-term exposed waiters. Mutation Research/Genetic Toxicology and Environmental Mutagenesis. 2005;588(1):22-7. [Scopus]

Zhang Y. Indoor air quality engineering: CRC press; 2004.

Crawley LH. Application of non-dispersive infrared (NDIR) spectroscopy to the measurement of atmospheric trace gases. 2008.

Tabatabaee.M. Calculation of building installations(in persian). 16, editor: Roozbahan; 2013. 52 p.

ISO. 16000-8 Indoor air -Part 8: Determination of local mean ages of air in buildings for characterizing ventilation conditions. Indoor air -Part 8: Determination of local mean ages of air in buildings for characterizing ventilation conditions2007.

Sandberg M, Sjöberg M. The use of moments for assessing air quality in ventilated rooms. Building and Environment. 1983;18(4):181-97. [Scopus]

Kwon K-S, Lee I-B, Han H-T, Shin C-Y, Hwang H-S, Hong S-W, et al. Analysing ventilation efficiency in a test chamber using age-of-air concept and CFD technology. biosystems engineering. 2011;110(4):421-33. [Scopus]

Van Buggenhout S, Van Brecht A, Özcan SE, Vranken E, Van Malcot W, Berckmans D. Influence of sampling positions on accuracy of tracer gas measurements in ventilated spaces. Biosystems Engineering. 2009;104(2):216-23. [Scopus]

Buratti C, Mariani R, Moretti E. Mean age of air in a naturally ventilated office: Experimental data and simulations. Energy and Buildings. 2011;43(8):2021-7. [Scopus]

ACGIH(American Conference of Governmental Industrial Hygienists). Industrial Ventilation A Manual of Recommended Practice for Desin. 28th ed 2013. Cincinatti, Ohio.

Brauer RL. Safety and health for engineers: 2006. Published by John Wiley & Sons, Inc. Hoboken, New Jersey Published simultaneously in Canada. [Scopus]

ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers). Ventilation for Acceptable Indoor Air Quality. Normative Appendix E-Table E-1. 2007. [Scopus]

ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers) American Society of Heating RaA-CE. Ventilation of Health Care Facilities. 75 Support Spaces2013. [Scopus]

  • Abstract Viewed: 405 times
  • PDF (فارسی) Downloaded: 172 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Developed By

Open Journal Systems

Language

  • فارسی
  • English

Information

  • For Readers
  • For Authors
  • For Librarians
  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

Creative Commons License

This journal is distributed under the terms of CC BY-NC 4.0.

ISSN-Online: 2383-1901| ISSN-Print: 2345-2455

                      https://goo.gl/maps/Q5TCJTUWtv7nqhe1A

Powered by OJSPlus