Publisher: School of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences
  • Register
  • Login

Archives of Advances in Biosciences

  • Home
  • Journal Info
    • Objectives and Scope
    • About the Journal
    • Editorial Board
    • Privacy Statement
    • Financial Policies
    • Indexing/Abstracting
    • Journal History
    • Announcements
  • Issues
    • Current
    • Archives
  • Journal Policies
    • Ethical Guidelines
    • Conflict of Interest
    • Copyright
    • Code of Publishing Ethics
    • Principles of Transparency
    • Allegations of Misconduct
    • Post-Publication Discussions and Corrections
    • Editorial Policies
    • Using Artificial Intelligence (AI)
    • Article Withdrawal
    • Complaints Process
  • Guidelines
    • Author Guidelines
    • Reviewer Guidelines
    • Journal Designer Guidelines
    • Journal Language Editor Guidelines
    • Policies of Peer Review
    • FAQ
  • Manuscript Template
    • Original Article
    • Review Article
    • Case Reports
    • Short Communication
  • Submit
  • Contact Us
Advanced Search
  1. Home
  2. Archives
  3. Vol. 3 No. 1 (2012): Winter
  4. Short Communication

Vol. 3 No. 1 (2012)

April 2012

Increasing of radiographic clinical value by using of Radio Photo Electrostatic imaging system (Xeroradiography)

  • Mojtaba Navvabpour
  • Naeima Navvabpour

Archives of Advances in Biosciences, Vol. 3 No. 1 (2012), 9 April 2012
https://doi.org/10.22037/jps.v3i1.2938 Published: 2012-03-14

  • View Article
  • Download
  • Cite
  • Statastics
  • Share

Abstract

     Ordinary Radiographic film sensitive emulsion is formed by crystals which are composed by millions of ions. According to the film texture, image constructive units number that interfere the image resolution are not increased more than a certain limitation in area unite. This innovation is to present an imaging system that to compare with common similar system has precedence such as highly image resolution, image edge sharpnessenhancement, contrast improvement, patient does reduction, rapid processing and cost decrease.

The "Xero" technique is different physical method for  imaging procedures in which instead of using the photochemical function, electrostatic effect has been used. The latent electrostatic images develop through toner powder, Because the toner powder particles are fine grain as small as a few compound molecules, Consequently, in the new method, image constructive units number which are described as the toner powder particles are much many more in number than crystals of radiographic films. Xeroradiophotography system is designed and constructed based on xero physical phenomenon in which image can be formed by taking advantage of both, X-Ray and visible light complex procedure for the purpose of X-Rays quality and patients body tissue side effect reduction at the time of exposure. This system has already been made as the first archetype in the world that is possible for optimum improving soon.

Keywords:
  • Xeroradiography
  • Latent imagem
  • Electrostatic
  • Resolution
  • Sharpness
  • PDF

How to Cite

Navvabpour, M., & Navvabpour, N. (2012). Increasing of radiographic clinical value by using of Radio Photo Electrostatic imaging system (Xeroradiography). Archives of Advances in Biosciences, 3(1). https://doi.org/10.22037/jps.v3i1.2938
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX
  • Abstract Viewed: 327 times
  • PDF Downloaded: 185 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Developed By

Open Journal Systems

Information

  • For Readers
  • For Authors
  • For Librarians
  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

Address: P.O. Box: 19395-4618, Darband St., Qods Sq.,Tehran, Iran.

Tel: +98-21-22707346

eISSN: 2783-1264

 Archives of Advances in Biosciences is an open access article under the terms of the Creative Commons Attribution -NonCommercial 4.0 International License.( CC BY-NC 4.0)

Powered by OJSPlus