April 2014

Determination of the Amount of Bioaerosols in Hospital Environments

  • Mohamadreza Massoudinejad
  • Elham Niknahad

Irtiqa Imini Pishgiri Masdumiyat (Safety Promotion and Injury Prevention), Vol. 1 No. 4 (2013), 20 April 2014 , Page 198-204
https://doi.org/10.22037/meipm.v1i4.6095 Published: 2014-04-19

  • View Article
  • Download
  • Cite
  • References
  • Statastics
  • Share

Abstract

Background and Objective: Bioaerosols are particles of microbes, viruses and derivatives; they exist in a wide variety of shapes and sizes and can be measured with different air samplers. The purpose of this study is the determination of bacterial aerosol in the air of hospitals and the determination of contaminated areas for disinfection proceedings by hospital health care teams, by selecting the most appropriate and efficient system for air conditioning.

Materials and Methods: This study was carried out at Tehran Ayatolah Taleghani Hospital. 35 most sensitive locations were chosen to reflect and be representative of the entire environment of the hospital. In the first phase, the three media were simultaneously put in the sampler each sample was repeated three times in the same conditions and then medium incubated in the incubator at a temperature of 37.2 degrees Celsius. After 24 or 48 hours, the numbers of colonies were counted. In the second phase the same locations were sampled again, at this stage, only thirty minute duration was sampled.

Results: All problems were located in different parts of the women’s toilets. .The colonies grow in a gram positive and gram negative specific medium and comparison with the standard indicators status of these settings was evaluated.

Conclusion: Bioaerosols can cause secondary hospital infections and this problem in patients with low immunity levels would be problematic. Factors such as humidity, sampling method, temperature, population, place and sampling time have a significant role in increasing the amount of bioaerosols in the air.

How to cite this article: Massoudinejad M, Niknahad E. Determination of the Amount of Bioaerosols in Hospital Environments. Irtiqa Imini Pishgiri Masdumiyat (Safety Promotion and Injury Prevention).2014; 4(1):198-204.

Keywords:
  • Air Pollution
  • Air Sampling
  • Hospital Infections
  • Bioaerosol
  • Bacteria
  • PDF

How to Cite

1.
Massoudinejad M, Niknahad E. Determination of the Amount of Bioaerosols in Hospital Environments. Irtiqa Imini Pishgiri Masdumiyat [Internet]. 2014 Apr. 19 [cited 2026 Jul. 23];1(4):198-204. Available from: https://journals.sbmu.ac.ir/spip/article/view/6095
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX

References

- Pasquarella C, Pitzurra O, Savino A. The index of microbial air contamination.Journal of hospital infection. 2000;46(4):241-56.

- Pant K, Crowe C, Irving P. On the design of miniature cyclones for the collection of bioaerosols.Powder Technology. 2002;125(2):260-5

- Sillanpää M, Geller MD, Phuleria HC, Sioutas C. High collection efficiency electrostatic precipitator for in vitro cell exposure to concentrated ambient particulate matter (PM). Journal of Aerosol Science. 2008;39(4):335-47.

- Zhen S, Li K, Yin L, Yao M, Zhang H, Chen L, et al. A comparison of the efficiencies of a portable BioStageimpactor and a Reuter centrifugal sampler (RCS) High Flow for measuring airborne bacteria and fungi concentrations. Journal of Aerosol Science. 2009;40(6):503-13.

- Wu Y, Shen F, Yao M. Use of gelatin filter and BioSampler in detecting airborne H5N1 nucleotides, bacteria and allergens. Journal of Aerosol Science. 2010; 41(9):869-79.

- Griffiths W, Bennett A, Speight S, Parks S. Determining the performance of a commercial air purification system for reducing airborne contamination using model micro-organisms: a new test methodology. Journal of Hospital Infection. 2005;61(3):242-7.

- Durand KT, Muilenberg ML, Burge HA, Seixas NS. Effect of sampling time on the cultivability of airborne fungi and bacteria sampled by filtration. Annals of occupational Hygiene. 2002;46(1):113-8.

- Obbard JP, Fang LS. Airborne concentrations of bacteria in a hospital environment in Singapore.Water, Air, and Soil Pollution. 2003; 144(1-4):333-41.

- Li A, Liu Z, Zhu X, Liu Y, Wang Q. The effect of air-conditioning parameters and deposition dust on microbial growth in supply air ducts. Energy and Buildings. 2010; 42(4):449-54.

- Tang C-S, Chung F-F, Lin M-C, Wan G-H. Impact of patient visiting activities on indoor climate in a medical intensive care unit: a 1-year longitudinal study. American journal of infection control. 2009;37(3):183-8.

- Wan G-H, Chung F-F, Tang C-S. Long-term surveillance of air quality in medical center operating rooms.American journal of infection control. 2011;39(4):302-8.

- Vahdat K, Rezaee R, Gharibi O. Bacteriology of hospital-acquired infection and antibiotic resistance in a hospital university of Bushehr Port Fatemeh Zahra (s) in 2002-2003. ISMJ. 2005;7(2):135-40.

- Ghorbani-Shahna F, Joneidi-Jafari A, Yousefi-Mashouf R, Mohseni M, Shirazi J. Type and Concentration of Bioaerosols in the Operating Room of Educational Hospitals of Hamadan University of Medical Sciences and Effectiveness of Ventilation Systems, in Year 2004.

- Chobineh A, Rostami R, Tabatabai H. Investigation of diversity and density of bioaerosols in the air of educational hospitals of Shiraz University of Medical Science in 2008. Iran Work health 2008;6

- Lee SJ, Park JS, Im HT, Jung H-I.A microfluidic ATP-bioluminescence sensor for the detection of airborne microbes. Sensors and Actuators B: Chemical. 2008;132(2):443-8.

- Wu Y, Yao M. Inactivation of bacteria and fungus aerosols using microwave irradiation. Journal of Aerosol Science. 2010;41(7):682-93.

- Chen F, Yang X, Mak HK, Chan DW. Photocatalytic oxidation for antimicrobial control in built environment: A brief literature overview. Building and Environment. 2010;45(8):1747-54.

- Guan T, Yao M. Use of carbon nanotube filter in removing bioaerosols. Journal of Aerosol Science. 2010;41(6):611-20.

- Hwang GB, Jung JH, Jeong TG, Lee BU. Effect of hybrid UV-thermal energy stimuli on inactivation of< i> S. epidermidis and< i> B. subtilis bacterial bioaerosols. Science of the total environment. 2010;408(23):5903-9.

- Fletcher L, Noakes C, Beggs C, Sleigh P, editors. The importance of bioaerosols in hospital infections and the potential for control using germicidal ultraviolet irradiation. Proceedings of the First Seminar on Applied Aerobiology, Murcia, Spain, May; 2004.

  • Abstract Viewed: 772 times
  • PDF Downloaded: 274 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Developed By

Open Journal Systems

Language

  • فارسی
  • English

Information

  • For Readers
  • For Authors
  • For Librarians
  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

Creative Commons License

This journal is distributed under the terms of CC BY-NC 4.0.

ISSN-Online: 2383-1901| ISSN-Print: 2345-2455

                      https://goo.gl/maps/Q5TCJTUWtv7nqhe1A

Powered by OJSPlus