Publisher: School of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences
  • Register
  • Login

Archives of Advances in Biosciences

  • Home
  • Journal Info
    • Objectives and Scope
    • About the Journal
    • Editorial Board
    • Privacy Statement
    • Financial Policies
    • Indexing/Abstracting
    • Journal History
    • Announcements
  • Issues
    • Current
    • Archives
  • Journal Policies
    • Ethical Guidelines
    • Conflict of Interest
    • Copyright
    • Code of Publishing Ethics
    • Principles of Transparency
    • Allegations of Misconduct
    • Post-Publication Discussions and Corrections
    • Editorial Policies
    • Using Artificial Intelligence (AI)
    • Article Withdrawal
    • Complaints Process
  • Guidelines
    • Author Guidelines
    • Reviewer Guidelines
    • Journal Designer Guidelines
    • Journal Language Editor Guidelines
    • Policies of Peer Review
    • FAQ
  • Manuscript Template
    • Original Article
    • Review Article
    • Case Reports
    • Short Communication
  • Submit
  • Contact Us
Advanced Search
  1. Home
  2. Archives
  3. Vol. 4 No. 1 (2013): Winter
  4. Research/Original Articles

Vol. 4 No. 1 (2013)

October 2012

The effect of viewing conditions on reader performance in radiographic images

  • Maryam Mojiri
  • Karim Ghazi Khanloo Sani
  • Abbas Moghimbeigi

Archives of Advances in Biosciences, Vol. 4 No. 1 (2013), 31 October 2012
https://doi.org/10.22037/jps.v4i1.3956 Published: 2013-01-13

  • View Article
  • Download
  • Cite
  • Statastics
  • Share

Abstract

Accurate interpretation of radiographic images is dependent on viewing conditions. Recently the number of radiology departments has been increased so it needs to use a workstation for reporting. The aim of this study was assess monitor performance and the effect of viewing conditions on object detection. This investigation aimed to quantify the effects of changes in box brightness and ambient light level on reader performance. Radiographs of the contrast-details phantom were taken in multiple exposures and were viewed by six observers. The viewing test was performed in 50,100 and 150 lux of ambient light in compound with 1000,1500 and 2000 cd m-2 box brightness. The percentage of uniformity was also 85. The results were analyzed by SPSS software. Low contrast visibility generally increased when the ambient light was 100 lux. The greatest performance was obtained in 2000 cd m-2 brightness and 15% non uniformity in mentioned ambient lighting. Reader performance not affected by ambient light and view box luminance although it seems those factors influenced on detection of low-contrast features in some studies.

 

Keywords:
  • Radiography
  • Image
  • Observer performance
  • Detectability
  • PDF

How to Cite

Mojiri, M., Ghazi Khanloo Sani, K., & Moghimbeigi, A. (2013). The effect of viewing conditions on reader performance in radiographic images. Archives of Advances in Biosciences, 4(1). https://doi.org/10.22037/jps.v4i1.3956
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX
  • Abstract Viewed: 354 times
  • PDF Downloaded: 848 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Developed By

Open Journal Systems

Information

  • For Readers
  • For Authors
  • For Librarians
  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

Address: P.O. Box: 19395-4618, Darband St., Qods Sq.,Tehran, Iran.

Tel: +98-21-22707346

eISSN: 2783-1264

 Archives of Advances in Biosciences is an open access article under the terms of the Creative Commons Attribution -NonCommercial 4.0 International License.( CC BY-NC 4.0)

Powered by OJSPlus