Publisher: School of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences
  • Register
  • Login

Archives of Advances in Biosciences

  • Home
  • Journal Info
    • Objectives and Scope
    • About the Journal
    • Editorial Board
    • Privacy Statement
    • Financial Policies
    • Indexing/Abstracting
    • Journal History
    • Announcements
  • Issues
    • Current
    • Archives
  • Journal Policies
    • Ethical Guidelines
    • Conflict of Interest
    • Copyright
    • Code of Publishing Ethics
    • Principles of Transparency
    • Allegations of Misconduct
    • Post-Publication Discussions and Corrections
    • Editorial Policies
    • Using Artificial Intelligence (AI)
    • Article Withdrawal
    • Complaints Process
  • Guidelines
    • Author Guidelines
    • Reviewer Guidelines
    • Journal Designer Guidelines
    • Journal Language Editor Guidelines
    • Policies of Peer Review
    • FAQ
  • Manuscript Template
    • Original Article
    • Review Article
    • Case Reports
    • Short Communication
  • Submit
  • Contact Us
Advanced Search
  1. Home
  2. Archives
  3. Vol. 7 No. 2 (2016): Spring
  4. Research/Original Articles

Vol. 7 No. 2 (2016)

February 2016

MATLAB-based software for Size-Specific Dose Estimation (SSDE) in Computed Tomography Examinations

  • Daryoush Khoramian
  • Soroush Sistani

Archives of Advances in Biosciences, Vol. 7 No. 2 (2016), 2 February 2016 , Page 35-38
https://doi.org/10.22037/jps.v7i2.11728 Published: 2016-03-14

  • View Article
  • Download
  • Cite
  • Statastics
  • Share

Abstract

Primary and widely in use Computed Tomography (CT) dose descriptor is a volumetric CT Dose Index (CTDIv) that is usually measured by a pencil ionization chamber with active length of 100mm and polymethyl methacrylate (PMMA) phantom. CTDIv depends on scan parameters such as mAs, kV, collimation, tube rotation time but is independent of patient’s size and shape. For the purpose of a good estimation of dose received by the patients, American Association of Physicists in Medicine (AAPM) published the conversion factors for both 16 and 32cm (head and body phantoms respectively); through this, users can extract conversion factors according to lateral (LAT) and/or anterior-posterior (AP) sizes and calculate real CTDIv. Since this procedure is time consuming, we designed MATLAB-based software to reduce such calculations. To design the software, GUI toolbar of MATLAB software was used. To test the software, scan parameters of two patients for head and pelvis scan were read from PACS and lateral (LAT) and anterior-posterior (AP) sizes were measured. Finally, SSDEs were calculated for two patients by the software. The software can be measured based on AP and/or LAT measures and/or in special cases (under the age of 18) through patients' age.

Keywords:
  • SSDE
  • CTDIv
  • Graphical User Interface (GUI)
  • MATLAB
  • PDF

How to Cite

Khoramian, D., & Sistani, S. (2016). MATLAB-based software for Size-Specific Dose Estimation (SSDE) in Computed Tomography Examinations. Archives of Advances in Biosciences, 7(2), 35–38. https://doi.org/10.22037/jps.v7i2.11728
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX
  • Abstract Viewed: 493 times
  • PDF Downloaded: 936 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Developed By

Open Journal Systems

Information

  • For Readers
  • For Authors
  • For Librarians
  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

Address: P.O. Box: 19395-4618, Darband St., Qods Sq.,Tehran, Iran.

Tel: +98-21-22707346

eISSN: 2783-1264

 Archives of Advances in Biosciences is an open access article under the terms of the Creative Commons Attribution -NonCommercial 4.0 International License.( CC BY-NC 4.0)

Powered by OJSPlus