Objectives Infection control is one of the most important aspects of dentistry. Since intraoral radiographic films are directly in contact with the oral environment, microbial contamination may transmit infectious diseases. The purpose of this study was to investigate the frequency of microbial contamination of intraoral radiographic films and compare the probable microbial contamination of two intraoral radiographic film brands available in the Iranian market.
Methods in this in vitro, experimental study, 900 radiographic films of two commercial brands, i.e. Intra X-ray and Carestream films were placed in aerobic, anaerobic, and fungal culture media immediately after removal from the packaging in sterile conditions. The samples were transferred to the respective culture media after incubation. The cultured bacteria were Gram-stained, and microscopically observed. The percentage of the contaminated intraoral radiographic films and the type of microbial contamination were reported. Data were analyzed using the Chi-square test.
Results Of all, 32.6% of the Carestream films and 44.6% of Intra X-ray films were infected by aerobic microorganisms, mostly Bacillus. In the anaerobic culture, the turbidity of the medium indicated the possible presence of microorganisms. In the fungal culture, no fungal hyphae were observed microscopically.
Conclusion The results of this study showed that intraoral films cannot be considered sterile. Intra X-ray radiographic films were significantly more contaminated than Care stream radiographic films.
- X-Ray Film
- Microbiology
- Infection Control
- Radiography
How to Cite
References
Sebastiani FR, Dym H, Kirpalani T. Infection control in the dental office. Dent Clin North Am. 2017;61(2):435-57.
Mustafa EA, Humam AK, Al-Mosuli TA. Evaluation of dental assistant awareness concerning infection control policy of blood borne diseases. J Int Dent Med Res. 2015;8(1):21-4.
Mallya SM. Quality Assurance and Infection Control. White and Pharoah's Oral Radiology E-Book: Principles and Interpretation. 2018; chap12:270.
White SC, Heslop EW, Hollender LG, Mosier KM, Ruprecht A, Shrout MK. Parameters of radiologic care: An official report of the American Academy of Oral and Maxillofacial Radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2001;91(5):498-511.
Thomas S, Agarwal M, Mehta G. Intraoperative glove perforation—singleversus double gloving in protection against skin contamination. Postgrad Med J. 2001;77(909):458-60.
Bushong SC. Radiologic science for technologists-E-book: physics, biology, and protection: Elsevier Health Sciences; 2018. Chap:12:P: 208.
Waltz PK, Zuckerbraun BS. Surgical site infections and associated operative characteristics. Surg. Infect. 2017;18(4):447-50.
European Directorate for the Quality of Medicines & HealthCare: Microbiological Quality of non-sterile Pharmaceutical Preparations and Substances for Pharmaceutical use. European Pharmacopoeia 70. 2011, Strasbourg: Chap5.1.4, EDQM.
Carroll KC, Butel JS, Morse SA. Jawetz Melnick & Adelbergs Medical Microbiology 27 E. McGraw Hill Professional; 2015 Chap:11:P:175-8.
Ranjbari M, Yaghmaei M, Hakemi-Vala M, Hosseinpour S. Assessment of bacterial contamination of the external surface of anesthetic cartridges. J Dent Sch. 2015;33(4):277-81.
Fox M, Harvey JM. An investigation of infection control for x-ray cassettes in a diagnostic imaging department. Radiography. 2008;14(4):306-11.
Kalathingal S, Youngpeter A, Minton J, Shrout M, Dickinson D, Plummer K, et al. An evaluation of microbiologic contamination on a phosphor plate system: is weekly gas sterilization enough? Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010;109(3):457-62.
Souza TM, Castro RD, Vasconcelos LC, Anjos Pontual A, Perez FM, Anjos Pontual ML. Microbial contamination in intraoral phosphor storage plates: the dilemma. Clin Oral Invest. 2017;21(1):301-7.
Negron W, Mauriello SM, Peterson CA, Arnold R. Cross-contamination of the PSP sensor in a preclinical setting. J Dent Hyg. 2005;79(3):8.
Gumru B, Tarcin B, Idman E. Cross-contamination and infection control in intraoral digital imaging: A comprehensive review. Oral Radiol. 2020;6:1-9.
Bartoloni JA, Chariton DG, Flint DJ. Infection control practices in dental radiology. Gen Dent. 2003;51(3):264-71.
Freitas CVS, Dias LS, Araújo CS, Silva VC, Neto VM, Souza JIL. Assessment of microbiological contamination of radiographic devices in School of Dentistry. Braz Dent Sci. 2012;15(1):39-46.
Fernandes LM, Zapata RO, Rubira-Bullen IR, Capelozza AL. Microbiologic cross-contamination and infection control in intraoral conventional and digital radiology. RGO. 2013;61(4):609-14.
- Abstract Viewed: 208 times
- PDF Downloaded: 123 times