Objectives Impression accuracy is the main determinant of the fit, form and function of prosthetic restorations. Polyvinyl siloxane (PVS) is the material of choice in most clinical situations. The purpose of this paper is to provide an up-to-date review of scientific articles which discuss the dimensional accuracy of PVS impression material using various impression techniques, tray types and spacers. Besides, the procedure, advantages and disadvantages of commonly used impression techniques, technique modifications and innovations are also reviewed.
Method An electronic search of scientific papers from 1990 to 2018 was carried out using MEDLINE and Google Scholar databases using the search terms “accuracy and polyvinyl siloxane and impression technique” and “accuracy and addition silicone and impression technique”.
Results Searching the key words yielded a total of 312 articles. By application of inclusion and exclusion criteria, the obtained results were further reduced to 35 citations.
Conclusion Impression technique is a critical variable in the accuracy of PVS impressions. Dual-phase 2-step technique with 1 to 2 mm space for the light body is proven to be highly accurate and is still considered as the standard technique. The use of 2-step technique without providing a space for the wash material is rejected by the literature. Triple-phase 2-step techniques including “matrix impression system” have also functioned well and even superior to traditional dual-phase 2-step technique. Papers suggest that custom trays do not significantly improve the accuracy of impressions and rigid stock trays are suitable alternatives- Vinyl Polysiloxane
- Dental Impression Technique
- Dimensional Measurement Accuracy
How to Cite
References
Nissan J, Laufer BZ, Brosh T, Assif D. Accuracy of three polyvinyl siloxane putty-wash impression techniques. J Prosthet Dent. 2000 Feb;83(2):161-5.
Amini P, Rahpeyma A, Hejazi M. Comparative analysis of dimensional accuracy of two types of silicone impression materials: Optosil and Elite-HD. J Dent Mater Tech. 2017 Mar;6(1):1-6.
Punj A, Bompolaki D, Garaicoa J. Dental impression materials and techniques. Dent Clin North Am. 2017 Oct;61(4):779-796.
Donovan TE, Chee WW. A review of contemporary impression materials and techniques. Dent Clin North Am. 2004 Apr;48(2):vi-vii, 445-70.
Rubel BS. Impression materials: A comparative review of impression materials most commonly used in restorative dentistry. Dent Clin North Am. 2007 Jul;51(3):629-42.
Garrofé AB, Ferrari BA, Picca M, Kaplan AE. Linear dimensional stability of elastomeric impression materials over time. Acta Odontol Latinoam. 2011;24(3):289-94.
Jamshidy L, Mozaffari HR, Faraji P, Sharifi R. Accuracy of the one-stage and two-stage impression techniques: A comparative analysis. Int J Dent. 2016;2016:7256496.
Naumovski B, Kapushevska B. Dimensional stability and accuracy of silicone - based impression materials using different impression techniques - a literature review. Pril (Makedon Akad Nauk Umet Odd Med Nauki). 2017 Sep;38(2):131-8.
Pandey A, Mehtra A. Comparative study of dimensional stability and accuracy of various elastomeric materials. IOSR- JDMS. 2014 Mar;13(3):40-5.
Caputi S, Varvara G. Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel two-step putty/light-body impression technique: an in vitro study. J Prosthet Dent 2008 Apr;99:274-81.
Prithviraj D, Pujari M, Garg P, Shruthi D. Accuracy of the implant impression obtained from different impression materials and techniques. J ClinExp Dent. 2011;3(2):106-11.
Idris B, Houston F, Claffey N. Comparison of the dimensional accuracy of one and two-step techniques with the use of putty/wash addition silicone impression materials. J Prosthet Dent. 1995 Nov;74(5):535-41.
Amini P, Tavallaei M. Effects of rewash on the accuracy of stone dies produced by putty-wash technique. J Kerman Univ Med Sci. 2013;20(2):169-78.
Varvara G, Murmura G, Sinjari B, Cardelli P, Caputi S. Evaluation of defects in surface detail for monophase, 2-phase, and 3-phase impression techniques: an in vitro study. J Prosthet Dent. 2015 Feb;113(2):108-13.
Livaditis GJ. The matrix impression system for fixed prosthodontics. J Prosthet Dent. 1998 Feb;79(2):208-16.
Samet N, Shohat M, Livny A, Weiss EI. A clinical evaluation of fixed partial denture impressions. J Prosthet Dent. 2005 Aug;94(2):112-7.
Shah S, Sundaram G, Bartlett D, Sherriff M. The use of a 3D laser scanner using superimpositional software to assess the accuracy of impression techniques. J Dent. 2004;32(8):653-8.
Amini P, Rahimi M. Accuracy and dimensional stability of two polysiloxane putty-wash impression techniques. J Dent (Shiraz). 2009;9(4):338-43.
Haralur SB, SaadToman M, Ali Al-Shahrani A, Ali Al-Qarni A. Accuracy of multiple pour cast from various elastomer impression methods. Int J Dent. 2016 Nov; 2016:1-6.
Pande NA, Parkhedkar RD. An evaluation of dimensional accuracy of one-step and two-step impression technique using addition silicone impression material: an in vitro study. J Indian Prosthodont Soc (July-Sept 2013) 13(3):254-9.
Basapogu S, Pilla A, Pathipaka S. Dimensional accuracy of hydrophilic and hydrophobic vps impression materials using different impression techniques - An Invitro Study. J Clin Diagn Res. 2016 Feb;10(2):ZC56-9.
Millar BJ, Dunne SM, Robinson PB. In vitro study of the number of surface defects in monophase and two-phase addition silicone impressions. J Prosthet Dent. 1998 Jul;80(1):32-5.
Mishra S, Chowdhary R. Linear dimensional accuracy of a polyvinyl siloxane of varying viscosities using different impression techniques. J InvestigClin Dent. 2010 Aug;1(1):37-46.
Singh K, Sahoo S, Prasad KD, Goel M, Singh A. Effect of different impression techniques on the dimensional accuracy of impressions using various elastomeric impression materials: an in vitro study. J Contemp Dent Pract. 2012 Jan-Feb;13(1):98-106.
Millar B. Dental know how: How to make a good impression (crown and bridge). Br Dent J. 2001Oct;191(7):402-5.
Vitti RP, da Silva MA, Consani RL, Sinhoreti MA. Dimensional accuracy of stone casts made from silicone-based impression materials and three impression techniques. Braz Dent J. 2013 Oct;24(5):498-502.
Franco EB, da Cunha LF, Herrera FS, Benetti AR. Accuracy of single-step versus 2-step double-mix impression technique. ISRN dentistry. 2011;2011:1-5.
Sayed ME, Sayed M, Al-Makramani B, Al-Sanabani F, Mohamed M. Effect of intermixing brands on the dimensional accuracy of master cast using putty-wash impression technique. J Contemp Dent Pract. 2016 Sep;17(9):734-9.
Fenske C. The influence of five impression techniques on the dimensional accuracy of master models. Braz Dent J. 2000;11(1):19-27.
Mann K, Davids A, Range U, Richter G, Boening K, Reitemeier B. Experimental study on the use of spacer foils in two-step putty and wash impression procedures using silicone impression materials. J Prosthet Dent. 2015 Apr;113(4):316-22.
Hung SH, Purk JH, Tira DE, Eick JD. Accuracy of one-step versus two-step putty wash addition silicone impression technique. J Prosthet Dent. 1992;67(5):583-9
Chugh A, Arora A, Singh VP. Accuracy of different putty-wash impression techniques with various spacer thickness. Int J Clin Pediatr Dent. 2012 Jan;5(1):33-8.
Dugal R, Railkar B, Musani S. Comparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study. J Int Oral Health. 2013 Oct;5(5):85-94.
Kumari N, Nandeeshwar DB. The dimensional accuracy of polyvinyl siloxane impression materials using two different impression techniques: An in vitro study. J Indian Prosthodont Soc. 2015 Jul-Sep;15(3):211-7.
Levartovsky S, Zalis M, Pilo R, Harel N, Ganor Y, Brosh T. The effect of one-step vs. two-step impression techniques on long-term accuracy and dimensional stability when the finish line is within the gingival sulcular area. J Prosthodont. 2014;23(2):124-33.
Nissan J, Rosner O, Bukhari MA, Ghelfan O, Pilo R. Effect of various putty-wash impression techniques on marginal fit of cast crowns. Int J Periodontics Restorative Dent. 2013;33(1):37-42.
Kumar MP, Patil SG, Dheeraj B, Reddy K, Goel D, Krishna G. A Comparison of Accuracy of Matrix Impression System with Putty Reline Technique and Multiple Mix Technique: An In Vitro Study. J Int Oral Health. 2015 Jun;7(6):48-53.
Livaditis GJ. Comparison of the new matrix system with traditional fixed prosthodontic impression procedures. J Prosthet Dent. 1998;79:200-7.
Gonçalves F, Popoff D, Castro C, Silva G, Magalhães C, Moreira A. Dimensional stability of elastomeric impression materials: a critical review of the literature. Eur J ProsthodontRestor Dent. 2011;19(4):163-6.
Gordon GE, Johnson GH, Drennon DG. The effect of tray selection on the accuracy of elastomeric impression materials. J Prosthet Dent. 1990;63(1):12-5.
Balkenhol M, Ferger P, Wostmann B. Dimensional accuracy of 2-stage putty-wash impressions: influence of impression trays and viscosity. The International J Prosthodont. 2007 Nov;20(6):573-5.
Hoyos A, Soderholm KJ. Influence of tray rigidity and impression technique on accuracy of polyvinyl siloxane impressions. Int J Prosthodont. 2011;24(1):49-54.
Abuasi HA, Wassell RW. Comparison of a range of addition silicone putty-wash impression materials used in the one-stage technique. Eur J Prosthodont Restor Dent. 1994 Mar;2(3):117-22.
Rathee S, Eswaran B, Eswaran M, Prabhu R, Geetha K, Krishna G, et al. A comparison of dimensional accuracy of addition silicone of different consistencies with two different spacer designs - In-vitro Study. J Clin Diagn Res. 2014 Jul;8(7):ZC38-41.
Saunders WP, Sharkey SW, Smith GM, Taylor WG. Effect of impression tray design and impression technique upon the accuracy of stone casts produced from a putty-wash polyvinyl siloxane impression material. J Dent. 1991;19(5):283-9.
Shillingburg HT, Hatch RA, Keenan MP, Hemphill MW. Impression materials and techniques used for cast restorations in eight states. J Am Dent Assoc. 1980 May;100(5):696-9.
Tjan AH, Nemetz H, Nguyen LT, Contino R. Effect of tray space on the accuracy of monophasic polyvinylsiloxane impressions. J Prosthet Dent. 1992 Jul;68(1):19-28.
Rajapur A, Dixit S, Hoshing C, Raikar SP. The influence of tray space and repeat pours on the accuracy of monophasic polyvinylsiloxane impression. J Contemp Dent Pract. 2012 Nov-Dec;13(6):824-9.
Kumar V, Aeran H. Evaluation of effect of tray space on the accuracy of condensation silicone, addition silicone and polyether impression materials: an in vitro study. J Indian Prosthodont Soc. 2012 Sep;12(3):154-60.
Sayed NM, Aly NH, Rayyan MM. The effect of different double-step impression techniques on accuracy of stone dies. Egypt Dent J. 2015 Jan;61:641-50.
Nissan J, Gross M, Shifman A, Assif D. Effect of wash bulk on the accuracy of polyvinyl siloxane putty-wash impressions. J Oral Rehabil .2002;29(4):357-61.
Shiozawa M, Takahashi H, Finger WJ, Iwasaki N. Effects of the space for wash materials on sulcus depth reproduction with addition-curing silicone using two-step putty-wash technique. Dent Mater J. 2013 Jan;32(1):150-5.
Chaimattayompol N, Park D. A modified putty-wash vinyl polysiloxane impression technique for fixed prosthodontics. J Prosthet Dent. 2007 Dec;98(6):483-5.
Nejatidanesh F, Koopaee H, MoniriFard R, Savabi O. Dimensional accuracy of three polyvinyl siloxane putty – wash impression techniques. J Dent Sch. 2009 winter ;26(4):412-9.
Leão MP, Pinto CP, Sponchiado AP, Ornaghi BP. Dimensional stability of a novel polyvinyl siloxane impression technique. Braz J Oral Sci. 2014 Apr-Jun ;13(2):118-23.
- Abstract Viewed: 611 times
- PDF Downloaded: 355 times