Comparison of Charge-Coupled Devices and Photostimulable Phosphor Storage Plates for Detection of Vertical Root Fractures in Endodontically Treated Teeth: An In Vitro Study
Journal of Dental School, Shahid Beheshti University of Medical Sciences,
Vol. 32 No. 1 (2014),
11 March 2019
,
Page 23-29
https://doi.org/10.22037/jds.v32i1.24758
Abstract
Objective: Vertical root fracture (VRF) is among the most common causes of endodontic treatment failures. This study aims to compare charge-coupled devices (CCD) and photostimulable phosphor plates (PSP) for detection of vertical root fractures in endodontically treated teeth.
Methods: In this diagnostic in vitro study, 40 maxillary anterior teeth were selected and after preparation and root canal filling, their crowns were cut 2mm above the cementoenamel junction (CEJ). The teeth were embedded in a piece of dried bone and radiographed using CCD and PSP with equal geometry at zero and 15° horizontal angles. VRFs were then induced and the fractured fragments were reattached. The teeth were radiographed again. Three observers evaluated the radiographs for detection of fracture line. Data were analyzed using the Proportion test and Wilcoxon’s Signed Ranks test.
Results: No significant difference was found between the two sensors in detection of VRFs [p-value (complete)= 0.592, p-value (absolute)= 1]. The sensitivity of the two sensors for detection of buccolingual and mesiodistal fractures was not significantly different [p-value BL (absolute)= 0.109, p-value BL (complete) 0.180] [p-value MD (complete)=0.593, p-value MD (absolute)= 0.102]. The sensitivity of both sensors for detection of buccolingual fracture was higher than for mesiodistal fractures (p<0.001).
Conclusion: CCD and PSP had equal efficacy for detection of VRFs in endodontically treated teeth.- Dental radiography
- Diagnosis
- Digital radiography
- Endodontically treated tooth
- Root canal
- Tooth
- Vertical root fracture
How to Cite
References
Cohen S, Hargreves K. Pathway of the pulp. 10th Ed. St Louis: The C.V. Mosby Co. 2011; Chap 1: 27-31.
Kositbowornchai S, Nuansakul R, Sikram S, Sinahawattana S, Saengmontri S. Root fracture detection: a comparison of direct digital radiography with conventional radiography. Dentomaxillofac Radiol 2001; 30: 106-109.
Andreasen JO, Andreasen FM. Text Book and Color Atlas of Traumatic Injuries to the Teeth. 4th
Ed. Copenhagen: Munskgaard Mosby 1994; Chap 2: 281-284.
Gunduz K, Avsever H, Orhan K, Çelenk P, Ozmen B, Cicek E, et al. Comparison of intraoral radiography and cone-beam computed tomography for the detection of vertical root fractures: an in vitro study. Oral Radiol 2013; 29: 6-12.
Tamse A. Vertical root fractures of Endodontically treated teeth. In: Ingle J. Nakland L. Naumgratner C. Endodontics. 6th Ed. NC Decker Inc 2008; Chap 20: 676-688.
Tamse A. Iatrogenic vertical root fractures in endodontically treated teeth. Endod Dent Traumatol 1988; 4: 190-196.
Ludlow JB, Mol A. Digital imaging. In: White SC, Pharoah MJ. Oral radiology, Principles and interpretation. 6th Ed. St. Louis: The C.V. Mosby Co. 2008; Chap7: 78-99.
Tsesis I, Kamburoğlu K, Katz A, Tamse A, Kaffe I, Kfir A. Comparison of digital with conventional radiography in detection of vertical root fractures in endodontically treated maxillary premolars: an ex vivo study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 124-128.
Versteeg CH, Sanderink GC, van der Stelt PF. Efficacy of digital intra-oral radiography in clinical dentistry. J Dent 1997; 25: 215-224.
Valizadeh S, Khosravi M, Azizi Z. Diagnostic accuracy of conventional, digital and Cone Beam CT in vertical root fracture detection. IEJ 2011; 6:15-20.
Wenzel A, Kirkevang LL. High resolution charge-coupled device sensor VS. Medium resolution photostimulable phosphor plate digital receptors for detection of root fractures in vitro. Dent Traumatol 2005; 21: 32-36.
Hassan B, Metska ME, Ozok AR, Stelt P, Wesselink PR. Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan. J Endod 2009; 35: 719- 722.
Lam EWN. Trauma to teeth and facial structures. In: White SC, Pharoah MJ. Oral radiology, Principles and interpretation. 6th Ed. St. Louis: The C.V. Mosby Co. 2008; Chap 29: 545-548.
Kamburoğlu K, Murat M, Pehlivan SY. The effects of digital image enhancement on the detection of vertical root fracture. Dent Traumatol 2010; 26: 47-51.
Varshosaz M, Tavakoli MA, Mostafavi M, Baghban AA. Comparison of conventional radiography with cone beam computed tomography for detection of vertical root fractures: an in vitro study. J Oral Sci 2010; 52: 593-597.
Bornstein MM, Wolner-Hanssen AB, Sendi P, von Arx T. Comparison of intraoral radiography and limited cone beam computed tomography for the assessment of root- fractured permanent teeth. Dent Traumatol 2009; 25:571-577.
likubo M, Kobayashi K, Mishima A, Shimoda S, Daimaruya T, lgarashi C, et al. Accuracy of intraoral radiography, multidetector helical CT, and limited cone-beam CT for the detection of horizontal tooth root fracture. Oral Surg Oral Med Oral pathol Oral Radiol Endod 2009; 108: 70- 74.
Kamburoğlu K, Murat S, Yűksei SP, Cebeci AR, Horasan S. Detection of vertical root fracture using cone-beam computerized tomography: an in vitro assessment. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e74-81.
Wenzel A, Haiter-Neto F, Frydenberg M, Kirkevang LL. Variable-resolution cone beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 939-945.
Nair MK, Nair UDP, Gröndahl HG, Webber RL, Wallace JA. Detection of artificially induced vertical radicular fractures using tuned aperture computed tomography. Eur J Oral Sci 2001; 109: 375-379.