Objective: When none of digital systems and scanners is accessible and it is essential to have digitized images of conventional radiographs, digital cameras can be used. The Aim of this study was to investigate whether digital images obtained by different resolutions of a digital camera are matched to the original radiographs in evaluation of caries.
Methods: In this diagnostic accuracy in vitro study the conventional radiographs of168 proximal surfaces of 84 teeth were produced, Then they were digitized with digital camera in three different resolutions; high (2048x1536), medium (1600x1200) and low resolution (480x460). Images were stored in Photoshop7.0 software, and were evaluated by5 observers to show the presence and depth of the caries. Cronbach’s α calculated inter-observers agreement and in order to calculate the agreement with original conventional radiographs Kappa index was used.
Results: In assessing the presence of caries, the agreement between low, medium and high resolutions with original radiographs were 0.286, 0.235 and 0 respectively. Also, assessing the depth of the caries agreement was reported0.21, 0.338 and 0.412 respectively. In most instances, there was a fair agreement between the different resolutions and original radiographs. The highest inter- observer’s agreement was reported in diagnosis of the presence of the caries with using high resolution (α=0.837) and the lowest inter-observer’s agreement was reported in diagnosis of the depth of the caries with medium resolution (α=0.762).There was no significant difference reported in observations of different resolutions and original images.
Conclusion: Using of high-resolution cameras did not show a significant difference with medium and low resolutions in caries evaluations. Therefore, considering the increase in the file size and difficulties in cameras selection, using of high-resolution digital cameras is not necessary in order to increase the diagnostic accuracy of digitized images.
- Dental Caries
- Dental Radiography
- Diagnosis
- Digital
- Photography
- ROC curve
How to Cite
References
Kajan ZD, Tayefeh Davalloo R, Tavangar M, Valizade F. The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries. Imaging Sci Dent 2015; 45: 81-87.
Malleshi SN, V G M, Raina A, Patil K. A subjective assessment of perceived clarity of indirect digital images and processed digital images with conventional intra-oral periapical radiographs. J Clin Diagn Res 2013; 7: 1793-1796.
Dove SB. Radiographic diagnosis of dental caries. J Dent Educ 2001; 65: 985-990.
Hellén-Halme K, Lith A. Carious lesions: diagnostic accuracy using pre-calibrated monitor in various ambient light levels: an in vitro study. Dentomaxillofac Radiol 2013; 42: 20130071.
Belém MD, Ambrosano GM, Tabchoury CP, Ferreira-Santos RI, Haiter-Neto F. Performance of digital radiography with enhancement filters for the diagnosis of proximal caries. Braz Oral Res 2013; 27: 245-251.
Kamburoglu K, Kolsuz E, Murat S, Yüksel S, Ozen T. Proximal caries detection accuracy using intraoral bitewing radiography, extraoral bitewing radiography and panoramic radiography.
Dentomaxillofac Radiol 2012; 41: 450-459.
White SC, Yoon DC. Comparative performance of digital and conventional images for detecting proximal surface caries. Dentomaxillofac Radiol 1997; 26: 32-38.
Syriopoulos K, Sanderink GC, Velders XL, van der Stelt PF. Radiographic detection of approximal caries: a comparison of dental films and digital imaging systems. Dentomaxillofac Radiol 2000; 29: 312-318.
Prapayasatok S, Janhom A, Verochana K, Pramojanee S. Digital camera resolution and proximal caries detection. Dentomaxillofac Radiol 2006; 35: 253-257.
Lee JK, Renner JB, Saunders BF, Stamford PP, Bickford TR, Johnston RE, et al. Effect of real- time teleradiology on the practice of the emergency department physician in a rural setting: initial experience. Acad Radiol 1998; 5: 533-538.
Chen YJ, Chen SK, Yao JC, Chang HF. The effects of differences in landmark identification on the cephalometric measurements in traditional versus digitized cephalometry. Angle Orthod 2004; 74: 155-161.
Goga R, Chandler NP, Love RM. Clarity and diagnostic quality of digitized conventional intraoral radiographs. Dentomaxillofac Radiol 2004; 33: 103-107.
Shrout MK, Potter BJ, Yurgalavage MH, Hildebolt CF, Vannier MW. 35-mm film scanner as an intraoral dental radiograph digitizer. II: Effects of brightness and contrast adjustments. Oral Surg Oral Med Oral Pathol 1993; 76: 510-518.
Hangiandreou NJ, O'Connor TJ, Felmlee JP. An evaluation of the signal and noise characteristics of four CCD-based film digitizers. Med Phys 1998; 25: 2020-2026.
Schulze RK, Rosing ST, D'Hoedt B. Contrast perception in digitized panoramic radiographs compared with their film-based origin. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2002; 94: 388-394.
Parissis N, Kondylidou-Sidira A, Tsirlis A, Patias P. Conventional radiographs vs digitized radiographs: image quality assessment. Dentomaxillofac Radiol 2005; 34: 353-356.
Fuge KN, Stuck AM, Love RM. A comparison of digitally scanned radiographs with conventional film for the detection of small endodontic instruments. Int Endod J 1998; 31: 123- 126.
Peretz B, Kaffe I, Amir E. Digital images obtained with a digital camera are not associated with a loss of critical information--a preliminary study. Br Dent J 2009; 206: discussion 268-269.
Valizadeh S, Tavakoli MA, Zarabian T, Esmaeili F. Diagnostic accuracy of digitized conventional radiographs by camera and scanner in detection of proximal caries. J Dent Res Dent Clin Dent Prospects 2009; 3: 126-131.
Berkhout WE, Verheij JG, Syriopoulos K, Li G, Sanderink GC, van der Stelt PF. Detection of proximal caries with high-resolution and standard resolution digital radiographic systems. Dentomaxillofac Radiol 2007; 36: 204-210.
Versteeg CH, Sandrerink GC, van der Stelt PF. Efficacy of digital intra-oral radiography in clinical dentistry. J Dent 1997; 25: 215-224.
Brault B, Hoskinson J, Armbrust L, Milliken G. Comparison of seven digital cameras for digitizing radiographs. Vet Radiol Ultrasound 2004; 45: 298-304.
Bader JD, Shugars DA, Bonito AJ. Systematic reviews of selected dental caries diagnostic and management methods. J Dent Educ 2001; 65: 960-968.
Miles DA. Imaging using solid-state detectors. Dent Clin North Am 1993; 37: 531-540.
Paurazas SB, Geist JR, Pink FE, Hoen MM, Steiman HR. Comparison of diagnostic accuracy of digital imaging by using CCD and CMOS-APS sensors with E-speed film in the detection of periapical bony lesions. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2000; 89: 356-362.
- Abstract Viewed: 189 times
- PDF Downloaded: 94 times