Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro)
Journal of Dental School, Shahid Beheshti University of Medical Sciences,
Vol. 34 No. 2 (2016),
17 March 2019
,
Page 100-108
https://doi.org/10.22037/jds.v34i2.24683
Abstract
Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements.
Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted into seven dry sheep mandibles. The length of the pins before the insertion was carefully measured by a digital caliper, (0.01mm accuracy). Imaging of the mandible performed using CBCT New Tom VGi. After image reconstruction by NNT Viewer, linear measurements were made on cross-sectional slices (thicknesses of 0.125, 0.5, 1 and 2mm) by three radiologists. The accuracy of measurements assessed using descriptive indices and compared between different slice thicknesses by repeated measures ANOVA.
Results: Repeated measures ANOVA showed a significant difference between different slice thicknesses (P=0.024). According to the least significant difference (LSD) test, the difference in absolute errors was significant in all thicknesses (P=0.024). Measurements at 0.125 mm thickness were significantly different from others, with a higher error rate (mean absolute error=0.17). Measurements at 0.5mm thickness showed a significant difference with those at 0.125 and 2mm (mean absolute error=0.15). Measurements at 2mm thickness were significantly different from those at 0.125 mm thickness (mean absolute error=0.13).The average error rate was lower in 2mm thickness and the measurements were more accurate.
Conclusion: A statistically significant difference was seam between CBCT measurements and actual sizes in different slice thicknesses. The differences were below 1mm, and clinically acceptable.
- Accuracy
- Cone-Beam Computed Tomography
- Dental Implants
- Dimensional Measurement
How to Cite
References
Al-Ekrish AA, Ekram M. A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions. Dentomaxillofac Radiol. 2011 Feb;40(2):67-75
Cavalcanti MGP, Rocha SS, Vannier MW. Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications. Dentomaxillofac Radiol. 2004 March; 33(3):170–6.
Scarf WC, Farman AG ,Sukokic P. Clinical application of cone-beam computed tomography in dental practice. J Can Dent Assoc. 2006 Feb;72(1):75-80
Sabban H, Mahdian M, Dhingra A, Lurie AG, Tadinada A. Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography. Imaging Sci Dent. 2015 Jun;45(2):73-80.
Chadwick JW, Lam EW. The effect of slice thickness and interslice interval on reconstructed cone beam computed tomographic images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010 Oct;110(4):e37-42
Sherrard JF , Rossouw PE, Benson BW, Carrillo R, Buschang PH. Accuracy and reliability of tooth and root lengths measured on cone-beam computed tomographs. Am J Orthod Dentofacial Orthop. 2010 Apr;137(4 Suppl):S100-8.
Ganguly R, Ruprecht A, Vincent S, Hellstein J, Timmons S, Qian F. Accuracy of linear measurement in the Galileos cone beam computed tomography under simulated clinical conditions. Dentomaxillofac Radiol. 2011 Jul;40(5):299-305.
Nikneshan S, Aval SH, Bakhshalian N, Shahab S, Mohammadpour M, Sarikhani S. Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles. Imaging Sci Dent. 2014 Dec;44(4):257-62.
Sezgin OS, Kayıpmaz S, Sahin B. The effect of slice thickness on the assessment of bone defect volumes by the Cavalieri principle using cone beam computed tomography. J Digit Imaging. 2013 Feb;26(1):115-8.
Esterla C, Bueno MR, Silva JA, Porto OCL, Leles CR, Azevedo BC. Effect of intracanal posts on dimensions of cone beam computed tomography images of endodontically treated teeth . Dent. press endod. 2011;1(1):28-36.
MacDonald D. Oral and Maxilliofacial Radiology–diagnostic approach. 1st Ed. Wiley-blackwell 2011; Chap 15: 296-8.
Boas EF, Flieschmann D. CT artifact: Cause and reduction techniques. Imaging Med. 2012; 4(2): 229-40.
Sheikhi M, Ghorbanizadeh S, Abdinian M, Goroohi H, Badrian H. Accuracy of linear measurement of galileos cone beam computed tomography in normal and different head position. Int J Dent. 2012;2012:214954.
Wood R, Sun Z, Chaudhry J, Tee BC, Kim DG, Leblebicioglu B, et al. Factors effecting the accuracy of buccal alveolar bone height measurements from cone-beam computed tomography images. Am J Orthod Dentofacial Orthop. 2013 Mar;143(3):353-63.
Ozer SY. Detection of vertical root fractures by using cone beam computed tomography with variable voxel sizes in an in vitro Model. J Endod. 2011 Jan;37(1):75-9.
Moshfeghi M, Tavakoli MA, Hosseini ET, Hosseini AT, Hosseini IT. Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT‑NewTom VG). Dent Res J (Isfahan). 2012 Dec;9(Suppl 1):S57-62.
Sirin Y, Guven K, Horasan S, Sencan S, Bakir B, Barut O, et al. The influence of secondary reconstruction slice thickness on NewTom 3G cone beam computed tomography–based radiological interpretation of sheep mandibularcondylefractures.Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010 Nov;110(5):638-47.
Shokri A, Khajeh S. In vitro comparison of the effect of different slice thicknesses on the accuracy of inear measurements on cone beam computed tomography images in implant sites. J Craniofac Surg. 2015 Jan; 26(1):157–60.
Fatemitabar SA, Nikgoo A. Multichannel computed tomography versus cone-beam computed tomography : linear accuracy of in vitro measurements of the maxilla for implant placement. Int J Oral Maxillofacial Implants. 2010 May-Jun;25(3):499-505.
- Abstract Viewed: 213 times