Publisher: School of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences
  • Register
  • Login

Archives of Advances in Biosciences

  • Home
  • Journal Info
    • About the Journal
    • Publisher
    • Editorial Board
    • Indexing/Abstracting
    • Objectives and Scope
    • Privacy Statement
    • Journal History
  • Issues
    • Current
    • Archives
  • Publication Ethics
    • Code of Publishing Ethics
    • Ethical Guidelines
  • Journal Policies
    • Article Processing Charge (APC)
    • Allegations of Misconduct
    • Archiving
    • Article Withdrawal
    • Complaints Process
    • Conflict of Interest
    • Copyright & Open Access Policy
    • Editorial Policies
    • Peer Review Policy
    • Post-Publication Discussions and Corrections
    • Principles of Transparency
    • Repository
    • Using Artificial Intelligence (AI)
  • Guidelines
    • Author Guidelines
    • Reviewer Guidelines
    • Journal Designer Guidelines
    • Journal Language Editor Guidelines
  • Manuscript Templates
    • Original Article
    • Review Article
    • Case Reports
    • Short Communication
    • Policy Note
  • Submit
  • FAQ
  • Contact Us
Advanced Search
  1. Home
  2. Archives
  3. Vol. 2 No. 2 (2011): Spring
  4. Research/Original Articles

Vol. 2 No. 2 (2011)

August 2011

Presentation of a new system in longitudinal tomography (micro layer tomography)

  • Mojtaba Navabpoor
  • Naeima Navvabpour

Archives of Advances in Biosciences, Vol. 2 No. 2 (2011), 6 August 2011
https://doi.org/10.22037/jps.v2i2.2326

  • View Article
  • Download
  • Cite
  • Statastics
  • Share

Abstract

Tomography or planigraphy is an X-Ray imaging system for preserving a certain plane of a radiography object by diffusing the other planes; however, the wanted plane does not obtain an optimum sharpness. Meanwhile, relatively nearer points to the rotating axes fixed point have lesser linear velocity than those of lying further from fixed point, consequently, Tomographic Bluring (obscuring) occur gradually, that gives rise the wanted plane to be somehow blurred that is known as "tomographic blurring", hence the clinical value of the image is diminished.This innovation could be an approach to improve current tomography systems by increasing image resolution and deep resolution and cost reduction. Micro layer tomography with benefit of fast X –Ray rotating velocity without tube movement has been designed to make images with deep resolution of millimeter fraction whilst, there is no need of digital images reconstruction instruments that allows statistical errors to fall off about zero, and high resolution images could be prepared in all planes (coronal, sagital and cross sectional. Likewise, the patient treatment and the system   maintenance cost are much less by many degrees compared with those in CT scan and MRI. In this system with increasing evolution, quick operation is highly exception, hence the tomographic slices could be prepared in about less than 0.02 second. The laboratory samples of this system have been a unique result for proving the new device preference.
Keywords:
  • Tomography
  • Deep Resolution
  • Blurring
  • Quick Rotation
  • PDF

How to Cite

Navabpoor, M., & Navvabpour, N. (2011). Presentation of a new system in longitudinal tomography (micro layer tomography). Archives of Advances in Biosciences, 2(2). https://doi.org/10.22037/jps.v2i2.2326
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX
  • Abstract Viewed: 336 times
  • PDF Downloaded: 186 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Developed By

Open Journal Systems

Information

  • For Readers
  • For Authors
  • For Librarians
  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

Address: P.O. Box: 19395-4618, Darband St., Qods Sq.,Tehran, Iran.

Tel: +98-21-22707346

eISSN: 2783-1264

 Archives of Advances in Biosciences is an open access article under the terms of the Creative Commons Attribution -NonCommercial 4.0 International License.( CC BY-NC 4.0)

Powered by OJSPlus