Introduction: This study sought to compare the fixation strength of mandibular angle fracture with 4- and 6-hole miniplates and different screw lengths using the Champy technique in sheep.
Materials and Methods: This is an in vitro study in 10 sheep mandibles. The soft tissue was removed and the mandibles were sectioned at the symphysis to obtain 20 hemimandibles. An artificial fracture was induced at the mandibular angle 1 cm farther from the most distal tooth using a saw. The hemimandibles were then randomly divided into two groups (n=10) for fixation with 4- or 6-hole miniplates without a bar. Each group was then randomly divided into 2 subgroups (n=5) for using 6 or 8-mm screws. The plates were adapted over the external oblique ridge. The distance from the closest hole to the fracture line was minimally 1 mm. Next, the hemimandibles were fixed to the holding arm of the universal testing machine by self-cure acrylic resin. Compressive load was applied to an occlusal jig prepared on the occlusal surface of mandibular molars at 3 cm distance from the fracture line at a crosshead speed of 1 mm/min until fracture. Data were analyzed using SPSS version 23.
Results: The mean fixation strength was not significantly different between 6-mm and 8-mm screws (P=0.243). The mean fixation strength in 6-hole miniplate group was significantly higher than that in 4-hole miniplate group (P=0.028).
Conclusion: The mean fixation strength in 6-hole miniplate group was significantly higher than that in 4-hole miniplate group. It seems that 6-hole miniplates provide higher fixation strength than 4-hole miniplates, irrespective of screw length. The mean fixation strength was not significantly different between 6-mm and 8-mm screws.
- Fixation Strength
- Miniplate
- Mandibular Angle Fracture
- Screw
How to Cite
References
References
Raymond J.fonseca,. Oral and maxillofacial trauma-E-book. Elsevier; 3th Edition, 2018 page 147 .
Thomas b.dodson, david h perrott,leonard b kaban et al.fixation of mandibular fracture:a comparative analysis of rigid internal fixation and standard fixation techniques.j oral maxillofac surg 48:362-366,1990 : 362-6
Zaky MM, Fayed NA, Shehab MF, Hellal US. The use of microplates for fixation of mandibular fractures: a systematic review. Journal of Medicine in Scientific Research. 2019 Jan 1;2(1):1.
T.m.g.j .van eijden :Biomechanics of the mandible . bcrit rev oral biol med.2000 ,11(1) :123-136
Champy M, Lodde JP, Schmitt R, Jaeger JH, Muster D. Mandibular osteosynthesis by miniature screwed plates via a buccal approach. Journal of maxillofacial surgery. 1978 Jan 1;6:14-21.
Boole JR, Holtel M, Amoroso P, Yore M. 5196 mandible fractures among 4381 active duty army soldiers, 1980 to 1998. The Laryngoscope. 2001 Oct;111(10):1691-6.
Ellis Iii E. Treatment methods for fractures of the mandibular angle. International journal of oral and maxillofacial surgery. 1999 Aug 1;28(4):243-52.
Perez R, Oeltjen JC, Thaller SR. A review of mandibular angle fractures. Craniomaxillofacial trauma & reconstruction. 2011 Jun;4(02):069-72.
Ribeiro-junior pd,magro-filho o,shastri ka,et al.In vitro evaluation of conventional and locking miniplate/screw systemfor the treatment of mandibular angle fracture.int oralmaxillofac surg 2010,39,-1109-14
Albogha MH, Mori Y, Takahashi I. Three-dimensional titanium miniplates for fixation of subcondylar mandibular fractures: Comparison of five designs using patient-specific finite element analysis.Journal of Cranio-Maxillofacial Surgery. 2018 Mar 1;46(3):391-7.
Bayram B, Araz K, Uckan S, Balcik C. Comparison of fixation stability of resorbable versus titanium plate and screws in mandibular angle fractures. Journal of oral and maxillofacial surgery. 2009 Aug 1;67(8):1644-8.
Kroon FH, Mathisson M, Cordey JR, Rahn BA. The use of miniplates in mandibular fractures: An in vitro study. Journal of Cranio-Maxillofacial Surgery. 1991 Jul 1;19(5):199-204.
Dolanmaz D, Uckan S, Isik K, Saglam H. Comparison of stability of absorbable and titanium plate and screw fixation for sagittal split ramus osteotomy. British Journal of Oral and Maxillofacial Surgery. 2004 Apr 1;42(2):127-32.
Esen A, Ataoğlu H, Gemi L. Comparison of stability of titanium and absorbable plate and screw fixation for mandibular angle fractures. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology. 2008 Dec 1;106(6):806-11.
Pektas ZO, Bayram B, Balcik C, Develi T, Uckan S. Effects of different mandibular fracture patterns on the stability of miniplate screw fixation in angle mandibular fractures.International journal of oral and maxillofacial surgery.2012 Mar1;41(3):339-43.
Korkmaz HH. Evaluation of different miniplates in fixation of fractured human mandible with the finite element method. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology. 2007 Jun 1;103(6):e1-3.
- Abstract Viewed: 208 times
- PDF Downloaded: 110 times