Parameters Used With Diode Lasers (808-980 nm) in Dentin Hypersensitivity Management: A Systematic Review

  • Haitham Abdelkarim-Elafifi
  • Isabel Parada Avendaño
  • Josep Arnabat Domínguez

Journal of Lasers in Medical Sciences, Vol. 13 (2022), , Page e3
Published 20 January 2022

  • View Article
  • Download
  • Cite
  • References
  • Statastics
  • Share

Abstract

Introduction: The present study aimed to describe parameters used with 808- to 980-nm wavelength diode lasers for managing dentin hypersensitivity and analyze their results.
Methods: The inclusion criteria were based on randomized controlled clinical trials using diode lasers at an 808-980 nm wavelength range in patients with dentine hypersensitivity with a minimum of 1-month follow-up. An electronic search for articles on Medline, PubMed, and Cochrane databases was performed. The risk of bias was assessed with the Cochrane collaboration tool.
Results: Our electronic search resulted in 130 papers, of which 11 articles met the inclusion criteria. A majority of the studies assessed dentine hypersensitivity using the Visual Analogue Scale, which ranged between 2.3 and 8.8 before treatment and significantly reduced to a mean value of 0.45-3.7 after diode laser application. The power settings ranged between 1.5 mW and 3 W with an emission mode of continuous wave, except for 2 authors who used chopped mode. The energy density varied from 2.5 to 128 J/cm2, and the exposure time was between 10 and 120 seconds. The authors applied a minimum of 1 to 4 treatment sessions with a 2-day to 1-week interval between them. Most of the studies mentioned the tooth surface as the treatment site but without describing the specific irradiation points.
Conclusion: Despite the heterogeneity of the analyzed variables, a statistically significant improvement in all laser groups as described. However, they cannot be compared homogenously.


Doi:10.34172/jlms.2022.03.

Keywords:
  • Dentin hypersensitivity; Diode laser; Laser therapy; Dentistry
  • PDF
  • Supplement 1

How to Cite

Abdelkarim-Elafifi, H., Parada Avendaño, I., & Arnabat Domínguez, J. (2022). Parameters Used With Diode Lasers (808-980 nm) in Dentin Hypersensitivity Management: A Systematic Review. Journal of Lasers in Medical Sciences, 13, e3. Retrieved from https://journals.sbmu.ac.ir/jlms/article/view/35255
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX

References

Raut CP, Sethi KS, Kohale B, Mamajiwala A, Warang A. Evaluation of diode laser and stannous flouride in the treatment of root sensitivity after access flap surgery: Randomized controlled clinical trial. J Ind Soc Periodontol. 2018; 22(2):158-163. doi:10.4103/jisp.jisp_2_18

Joshi I, Dodwad V, Tevatia S, Singla R. Comparative evaluation of the efficacy of diode laser as an adjunct to stannous fluoride in the management of dentinal hypersensitivity: A clinical study. Res Rev J Dent Sci. 2016;4(3):84‐9.

Rees JS, Addy M. A cross‐sectional study of dentine hypersensitivity. J Clin Periodontol 2002;29(11):997‐1003. doi:10.1034/j.1600-051x.2002.291104.x

Chabanski MB, Gillam DG, Bulman JS, Newman HN. The prevalence, distribution and severity of cervical dentine sensitivity in a population of patients referred to a specialist periodontology department. J Clin Periodontol. 1996;23(11):989-92. doi:10.1111/j.1600-051x.1996.tb00525.x

Yamaguchi M, Ito M, Miwata T, Horiba N, Matsumoto T, Nakamura H et al. Clinical study on the treatment of hypersensitive dentin by gaAlAs laser diode using the double blind test. Aichi Gakuin Daigaku Shigakkai Shi. 1990;28(2):703-707.

Gerschman JA, Ruben J, Gebart‐Eaglemont J. Low level laser therapy for dentinal tooth hypersensitivity. Aust Dent J. 1994; 39(6):353‐7. doi:10.1111/j.1834-7819. 1994.tb03105.x

Kumar NG, Mehta DS. Short‐term assessment of the Nd: YAG laser with and without sodium fluoride varnish in the treatment of dentin hypersensitivity – A clinical and scanning electron microscopy study. J Periodontol. 2005; 76(7):1140‐7. doi:10.1902/jop.2005.76.7.1140

Lopes AO, de Paula Eduardo C, Aranha ACC. Evaluation of different treatment protocols for dentin hypersensitivity: an 18-month randomized clinical trial. Lasers Med Sci 2017;32(5):1023–1030. doi:10.1007/s10103-017-2203-0

Machado AC, Viana ÍEL, Farias-Neto AM, Braga MM, de Paula Eduardo C, de Freitas PM, Aranha ACC. Is photobiomodulation (PBM) effective for the treatment of dentin hypersensitivity? A systematic review. Lasers Med Sci. 2018;33(4):745-753. doi:10.1007/s10103-017-2403-7

Lee SY, Jung HI, Jung BY, Cho YS, Kwon HK, Kim BI. Desensitizing efficacy of nano-carbonate apatite dentifrice and Er,Cr:YSGG laser: a randomized clinical trial. Photomed Laser Surg. 2015;33(1):9-14. doi:10.1089/pho.2014.3787

Moura GF, Zeola LF, Silva MB, Sousa SC, Guedes FR, Soares PV. Four-session protocol effectiveness in reducing cervical dentin hypersensitivity: A 24-week randomized clinical trial. Photobiomodul Photomed Laser Surg. 2019;37(2):117-123. doi:10.1089/photob.2018.4477

Yilmaz H, Yilmaz S, Cengiz E. Long-term effect of diode laser irradiation compared to sodium fluoride varnish in the treatment of dentine hypersensitivity in periodontal maintenance patients: A randomized controlled clinical study. J Photomed Laser Surg. 2011;29(11):721-5. doi:10.1089/pho.2010.2974

Yilmaz HG, Kurtulmus-Yilmaz S, Cengiz E, Bayindir H, Aykac Y. Clinical evaluation of Er,Cr:YSGG and GaAlAs laser therapy for treating dentine hypersensitivity: A randomized controlled clinical trial. J Dent. 2011;39(3):249-54. doi: 10.1016/j.jdent.2011.01.003

Tabibzadeh Z, Fekrazad R, Esmaeelnejad A, Shadkar M, Sadrabad Z, Ghojazadeh M. Effect of combined application of high- and low-intensity lasers on dentin hypersensitivity: A randomized clinical trial. J Dent Res Dent Clin Dent Prospects. 2018; 12(1): 49-55. doi:10.15171/joddd.2018.008

Sicilia A, Frechoso S, Suarez A, Angulo J, Pordomingo A, De Juan P. Immediate efficacy of diode laser application in the treatment of dentine hypersensitivity in periodontal maintenance patients: a randomized clinical trial. J Clin Periodontol. 2009; 36(8): 650-660. doi:10.1111/j.1600-051X.2009. 01433.x

Umberto R, Claudia R, Gaspare P, Gianluca T, Alessandro D. Treatment of dentine hypersensitivity by diode laser: A clinical study. Int J Dent. 2012; 2012 858950. doi:10.1155/2012/858950

Pourshahidi S, Ebrahimi H, Mansourian A, Mousavi Y, Kharazifard M. Comparison of Er,Cr:YSGG and diode laser effects on dentin hypersensitivity: a split-mouth randomized clinical trial. Clin Oral Investig. 2019;23(11):4051-4058. doi:10.1007/s00784-019-02841-z

Narayanan R, Prabhuji MLV, Paramashivaiah R, Bhavikatti SK. Low-level Laser Therapy in Combination with Desensitising Agent Reduces Dentin Hypersensitivity in Fluorotic and Non-fluorotic Teeth - A Randomised, Controlled, Double-blind Clinical Trial. Oral Health Prev Dent. 2019;17(6):547-556. doi:10.3290/j.ohpd.a43567

Naghsh N, Kachuie M, Kachuie M, Birang R. Evaluation of the effects of 660-nm and 810-nm low-level diode lasers on the treatment of dentin hypersensitivity. J Lasers Med Sci. 2020; 11(2):126-131. doi:10.34172/jlms.2020.22

Ishihata H, Finger WJ, Kanehira M, Shimauchi H, Komatsu M. In vitro dentin permeability after application of Gluma® desensitizer as aqueous solution or aqueous fumed silica dispersion. J Appl Oral Sci. 2011;19(2): 147-53.doi:10.1590/s1678-77572011000200011

Mahesuti A, Duan YL, Wang G, Cheng XR, Matis BA. Short-term Efficacy of Agents Containing KNO3 or CPP-ACP in Treatment of Dentin Hypersensitivity. Chin J Dent Res. 2014;17(1):43-7.

Stabholz A, Khayat A, Ravanshad S.H, McCarthy D.W, Neev J, Torabinejad M. Effects of Nd:YAG laser on apical seal of teeth after apicoectomy and retrofill. J Endod. 1992;18(8):371-5.

Umana M, Heysselaer D, Tielemans M, Compere P, Zeinoun T, Nammour S. Dentinal tubules sealing by means of diode lasers (810 and 980 nm): a preliminary in vitro study. Photomed Laser Surg. 2013;31(7):307-14. doi:10.1089/pho.2012.3443

Machado AC, Viana ÍEL, Farias-Neto AM, Braga MM, de Paula Eduardo C, de Freitas PM, Aranha ACC. Is photobiomodulation (PBM) effective for the treatment of dentin hypersensitivity? A systematic review. Lasers Med Sci. 2018;33(4):745-753. doi:10.1007/s10103-017-2403-7

Pinheiro AL, Cavalcanti ET, Pinheiro TI, Alves MJ, Miranda ER.,De Quevedo AS, Manzi CT, Vieira AL, Rolim AB. LLLT is an important tool to treat disorders of the maxillofa- cial region. J Clin Laser Med Surg. 1998;16(4):223-6

Joshi S, Gowda AS, Joshi C. Comparative evaluation of NovaMin desensitizer and Gluma desensitizer on dentinal tubule occlusion: a scanning electron microscopic study. J Periodontal Implant Sci. 2013; 43(6):269–275. doi:10.5051/jpis.2013.43.6.269

Liu Y, Gao J, Gao Y, Xu S, Zhan X, Wu B. In vitro study of dentin hypersensitivity treated by 980-nm diode laser. J Lasers Med Sci. 2013; 4(3): 111-9.

Jenkins PA, Carroll JD. How to report low-level laser therapy (LLLT)/photomedicine dose and beam parameters in clinical and laboratory studies. J Photomed Laser Surg. 2011; 29(12):785–787. doi:10.1089/pho.2011.9895

Hode L, Tun'er J. Laser Therapy Clinical Practice and Scientific Background. Prima Books AB: Grängesberg, Sweden: 2002.

Keshri GK, Gupta A, Yadav A, Sharma SK, Singh SB. Photobiomodulation with Pulsed and Continuous Wave Near-Infrared Laser (810 nm, Al-Ga-As) Augments Dermal Wound Healing in Immunosuppressed Rats. PLoS One. 2016 ;11(11): e0166705. doi:10.1371/journal.pone.0166705

Hamblin MR. How to write a good photobiomodulation article. Photobiomodul Photomed Laser Surg. 2019;37(6):325-326. doi:10.1089/photob.2019.4648

  • Abstract Viewed: 1480 times
  • PDF Downloaded: 277 times
  • Supplement 1 Downloaded: 14 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram
Make a Submission
Information
  • For Readers
  • For Authors
  • For Librarians
Open Journal Systems
Keywords
Current Issue
  • Atom logo
  • RSS2 logo
  • RSS1 logo
Browse
  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

Iranian Medical Laser Association 

                                        

 

This journal is distributed under the terms of CC BY-NC 3.0.
Design and publishing by SBMU journals. All credits and honors to PKP for their OJS. 

The template of this website is designed by Sinaweb