Publisher: Shahid Beheshti University of Medical Sciences
  • Submission
  • Register
  • Login

Journal of Dental School

  • Home
  • About
    • About the Journal
    • Journal Metrics
    • Editorial Team
    • Aims & Scope
    • Indexing & Abstracting
    • Open Access
    • Publication Fees
    • Privacy Statement
  • Articles & Issues
    • Current
    • Archive
    • Accepted Manuscripts
  • Policies & Process
    • Peer Review Process
    • Complaints And Appeals
    • Conflicts of Interest
    • Data and Reproducibility
    • Plagiarism
    • Post Publication
    • Misconducts
    • Preprint
    • Archiving
    • Editorial Independence
    • Copyright
  • For Authors
    • Authorship
    • Forms
    • Ethical Guidelines and Considerations
    • Reporting Guidelines
  • Submission
    • Submit a New Manuscript
    • Track Your Submission
    • Instructions for Authors
    • Download Original Article Template
    • Download Title Page Form
    • Download Publishing Agreement Form
  • Register
  • Contact
Advanced Search
  1. Home
  2. Archives
  3. Vol. 32 No. 2 (2014): Spring
  4. Original Article

Vol. 32 No. 2 (2014)

April 2014

Effect of Three Light Curing Protocols and Load Cycling on Microleakage of Class V Composite Restorations

  • Abdolrahim Davari
  • Alireza Daneshkazemi
  • Tahere Taghizadeh

Journal of Dental School, Vol. 32 No. 2 (2014), 27 April 2014 , Page 71-79
https://doi.org/10.22037/jds.v32i2.24800 Published: 2019-03-13

  • View Article
  • Download
  • Cite
  • References
  • Statastics
  • Share

Abstract

Objective: Different methods have been suggested to overcome the polymerization shrinkage of composite restorations. Changing the light curing protocol to improve polymerization by using new light curing units is among these methods. The new devices are more efficient, portable and durable and produce less heat. This study aimed to assess the marginal microleakage of class V composite restorations subjected to three different light curing protocols and mechanical cycles.

Methods: This was an in-vitro experimental study. Class V cavities measuring 2x3x1.5 mm were prepared on the buccal and lingual surfaces of 90 extracted human premolar teeth 1.5 mm above and below the cement enamel junction (CEJ). The samples were selected using convenience sampling and divided into 9 experimental groups of 10 each by using the Table of Random Numbers to  control for the bias. The cavities were restored with packable composite resin along with Tetric-N- Bond and cured using three light curing protocols of conventional (680 mW/cm2 for 30s), soft-start (380 mW/cm2 for 10s followed by 680 mW/cm2 for 20s) and pulse (680 mW/cm2 for 30s,1s interval and 1s of lighting). The teeth were then subjected to mechanical cycles of 0, 500,000 and 1,000,000 and immersed in 2% Fuchsin for 24h. The teeth were then sectioned in half from the middle of the restoration buccolingually and the degree of microleakage was evaluated under a stereomicroscope (Zeiss, Germany) with 40X magnification. Data were analyzed using the Kruskal Wallis and the Mann-Whitney tests.

Results: Despite the structural differences between the enamel and dentin margins, no significant difference was found in the degree of microleakage between the enamel (occlusal wall, p>0.05) and dentin (gingival wall, p>0.05) margins among the understudy groups.

Conclusion: The degree of marginal microleakage in soft-start (SS) polymerization was not significantly different from that in conventional and pulse polymerizations of class V composite restorations
Keywords:
  • Conventional
  • Mechanical cycles
  • Microleakage
  • Pulse
  • Soft-start.
  • PDF

How to Cite

Davari, A., Daneshkazemi, A., & Taghizadeh, T. (2019). Effect of Three Light Curing Protocols and Load Cycling on Microleakage of Class V Composite Restorations. Journal of Dental School, 32(2), 71–79. https://doi.org/10.22037/jds.v32i2.24800
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX

References

El-Korashy DI. Post-gel shrinkage strain and degree of conversion of preheated resin composite cured using different regimens. Oper Dent 2010; 35:172-179.

Knezevic A, Sariri K, Sovic I, Demoli N, Tarle Z. Shrinkage evaluation of composite polymerized with LED units using laser interferometry. Quintessence Int 2010; 41:417-425.

Heymann H, Swift EJ, Ritter AV, Sturdevants CM. Sturdevant`s art and science of Operative dentistry. 6th Ed. USA. St. Louis: The C. V. Mosby Co. 2013; Chap 9: 221-222.

Summit JB, Rabbins JW, Schawartz RS. Fundamentals of operative dentistry. 3rd Ed. Quintessence Publishing Co. 2006; Chap 10: 293-295.

Barros GK, Aguiar FH, Santos AJ, Lovadino JR. Effect of different intensity light curing modes on microleakage of two resin composite restorations. Oper Dent 2003; 28: 642-646.

Yang JY, ZhangSHY, Chen SH, Feng L. Effect of two light-curing modes on marginal adaptation and microhardness of packable posterior resin-based composites. J Clin Rehabil Tissue Engineering Res 2010; 14: 8904-8907.

Yazici AR, Celik C, Dayangac B, Ozgunaltay G. Effects of different light curing units/modes on the microleakage of flowable composite resins. Eur J Dent 2008; 2: 240-246.

Friedl KH, Schmalz G, Hiller KA, Märkl A. Marginal adaptation of class V restorations with and without “softstart-polymerization”. Oper Dent 2000; 25: 26-32.

Yap AU, Soh MS, Siow KS. Effectiveness of composite cure with pulse activation and soft-start polymerization. Oper Dent 2002; 27: 44-49.

Ratih DN, Palamara JE, Messer HH. Minimizing dentinal fluid flow associated with gapformation. J Dent Res 2006; 85: 1027-1031.

Yap AU, Ng SC, Siow KS. Soft-start polymerization: influence on effectiveness of cure and post gel shrinkage. Oper Dent 2001; 26: 260-266.

Yap AU, Soh MS, Siow KS. Post-gel shrinkage with pulse activation and soft start polymerization. Oper Dent 2002; 27: 81-87.

Hakimeh S, Vaidyanathan J, Houpt ML, Vaidyanathan TK, Von Hagen S. Microleakage of compomer classV restorations: effect of loadcycling, thermal cycling and cavity shape differences. J Prosthet Dent 2000; 83: 194-203.

Bedran-de-Castro AK, Pereira PN, Pimenta LA, Thompson JY. Effect of thermal and mechanical loadcycling on nanoleakage of class II restorations. J Adhes Dent 2004; 6: 221-226.

Mitsui FH, Bedran-de-Castro AK, Ritter AV, Cardoso PE, Pimenta LA. Influence of load cycling on marginal microleakage with two self-etching and two one-botle dentin adhesive systems in dentin. J Adhes Dent 2003; 5: 209-216.

Campos PE, Barceleiro Mde O, Sampaio-Filho HR, Martins LR. Evaluation of the cervical integrity during occlusal loading of Class II restorations. Oper Dent 2008; 33: 59-64.

Jang KT, Chung DH, Shin D, García-Godoy F. Effect of eccentric load cyclig on microleakage of Class V flowable and packable composite resin restorations. Oper Dent 2001; 26: 603-608.

Sarr M, Kane AW, Vreven J, Mine A, Van Landuyt KL, Peumans M, et al. Microtensile bond strength and interfacial characterization of 11 contemporary adhesives bonded to bur-cut dentin. Oper Dent 2010; 35: 94-104.

  • Abstract Viewed: 173 times
  • PDF Downloaded: 137 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Developed By

Open Journal Systems

Information

  • For Readers
  • For Authors
  • For Librarians

Make a Submission

Make a Submission
  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

e-ISSN: 2645-4351

Creative Commons License

This journal is open access and available under the Creative Commons Attribution-NonCommercial-NoDerivatives (CC BY-NC-ND) license (https://creativecommons.org/licenses/by-nc-nd/4.0/).

 
Powered by OJSPlus