Shahid Beheshti University of Medical Sciences
  • Register
  • Login

Journal of Lasers in Medical Sciences

  • Issues
    • Current Issue
    • Archives
  • Journal Info
    • About the Journal
    • Editorial Team
    • Indexing/Abstracting
    • Contact Us
  • Author Guideline
    • Submission Guide
    • Author Statement Form
    • Peer Review Process
    • Publication Fee
  • Ethics & Policies
    • Ethical Requirements
    • Authorship Rules
    • Withdrawal Regulations
    • Retraction Considerations
    • Privacy Statement
  • Reviewer Guideline
  • New Submission
Advanced Search
  1. Home
  2. Archives
  3. Vol. 7 No. 1 (2016): Winter
  4. Original Article

Vol. 7 No. 1 (2016)

January 2016

Surface Treatment by Different Parameters of Erbium:Yttrium–Aluminum–Garnet (Er:YAG) Laser: Scanning Electron Microscope (SEM) Evaluation

  • Nasim Chiniforush
  • Hanieh Nokhbatolfoghahaei
  • Abbas Monzavi
  • Edris pordel
  • Sajjad Ashnagar

Journal of Lasers in Medical Sciences, Vol. 7 No. 1 (2016), 26 January 2016 , Page 37-39
Published: 2016-01-26

  • View Article
  • Download
  • Cite
  • References
  • Statastics
  • Share

Abstract

Introduction: This study aimed to assess the Scanning Electron Microscope (SEM) analysis of tooth surface irradiated by erbium:yttrium–aluminum–garnet (Er:YAG) laser with various parameters.

Methods: Number of 25 extracted human third molars free of caries were used in this study. The teeth were put into 5 groups for laser irradiation as follows: group 1 (power: 0.5 W, Energy: 50 mJ); group 2 (power: 1 W, Energy: 100 mJ); group 3 (power: 1.5 W, Energy: 150 mJ); group 4 (power: 2 W, Energy: 200 mJ); group 5 (power: 2.5 W, Energy: 250 mJ). All samples were prepared by repetition rate of 10 Hz and duration of 230 μs, using a non-contact handpiece at a distance of 4 mm. Then, the samples were prepared for SEM examination.

Results: SEM evaluation of every 25 samples, treated by Er:YAG, showed that all groups had exposed dentinal tubules without any melted area or cracks.

Conclusion: In this study we used SEM to investigate ablated dentine with different parameters of Er:YAG laser energy. Our findings support these conclusions. All powers of laser below 3 W are proper for ablation, and make no cracks.

Keywords:
  • Dentinal tubules
  • Laser
  • Scanning electron microscopy
  • Er
  • YAG.
  • PDF

How to Cite

Chiniforush, N., Nokhbatolfoghahaei, H., Monzavi, A., pordel, E., & Ashnagar, S. (2016). Surface Treatment by Different Parameters of Erbium:Yttrium–Aluminum–Garnet (Er:YAG) Laser: Scanning Electron Microscope (SEM) Evaluation. Journal of Lasers in Medical Sciences, 7(1), 37–39. Retrieved from https://journals.sbmu.ac.ir/jlms/article/view/7479
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX

References

Schein MT, Bocangel JS, Nogueira GE, Schein PA. SEM evaluation of the interaction pattern between dentin and resin after cavity preparation using Er: YAG laser. J Dent. 2003;31(2):127-135. doi:10.1016/s0300-5712(03)00003-4.

Samad-Zadeh A, Harsono M, Belikov A, et al. The influence of laser-textured dentinal surface on bond strength. Dent Maters. 2011;27(10):1038-1044. doi:10.1016/j. dental.2011.07.005.

Shahabi S, Chiniforush N, Bahramian H, Monzavi A, Baghalian A, Kharazifard MJ. The effect of erbium family laser on tensile bond strength of composite to dentin in comparison with conventional method. Lasers Med Sci. 2013;28(1):139-142. doi:10.1007/s10103-012-1086-3.

Amaral FL, Colucci V, Souza-Gabriel AE, Chinelatti MA, Palma-Dibb RG, Corona SA. Bond durability in erbium: yttrium–aluminum–garnet laser-irradiated enamel. Lasers Med Sci. 2010;25(2):155-163.

Shirani F, Birang R, Malekipur MR, et al. Adhesion to Er: YAG laser and bur prepared root and crown dentine. Aust Dental J. 2012;57(2):138-143. doi:10.1111/j.1834- 7819.2012.01682.x.

Arami S, Shahabi S, Tabatabaie M, Chiniforush N, Morshedi E, Torabi S. Assessing microleakage of composite restorations in class V cavities prepared by Er:YAG laser irradiation or diamond bur. J Conserv Dent. 2014;17(3): 216–219. doi:10.4103/0972-0707.131778.

Pahlavan A, Mehmanchi M, Ranjbar Omrani L, Chiniforush N. Effect of air abrasion and erbium-doped yttrium aluminum garnet (Er: YAG) laser preparation on shear bond strength of composite to dentin. J Lasers Med Sci. 2013;4(3):127–130.

Freitas PM, Navarro RS, Barros JA, de Paula Eduardo C. The use of Er: YAG laser for cavity preparation: an SEM evaluation. Microsc Res Tech. 2007;70(9): 803-808. doi:10.1002/jemt.20470.

Nokhbatolfoghahaie H, Chiniforush N, Shahabi S, Monzavi A. Scanning electron microscope (SEM) Evaluation of tooth surface irradiated by different parameters of erbium: yttrium aluminium garnet (Er: YAG) laser. J Lasers Med Sci. 2012;3(2):51-55.

Ekworapoj P, Sidhu SK, McCabe JF. Effect of different power parameters of Er, Cr: YSGG laser on human dentine. Lasers Med Sci. 2007;22(3):175-182. doi:10.1007/s10103- 006-0426-6.

Igarashi A, Kato J, Takase Y, Hirai Y. Influence of output energy and pulse repetition rate of the Er: YAG laser on dentin ablation. Photomed Laser Surg. 2008;26(3):189-195.

Zach L, Cohen G. Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol. 1965;19(4):515-530. doi:10.1016/0030-4220(65)90015-0.

Sonntag, KD, Klitzman B, Burkes EJ, Hoke J, Moshonov J. Pulpal response to cavity preparation with the Er: YAG and Mark III free electron lasers. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1996;81(6): 695-702. doi:10.1016/s1079-2104(96)80076-x.

Rizoiu I, Kohanghadosh F, Kimmel AI, Eversole LR. Pulpal thermal responses to an erbium, chromium: YSGG pulsed laser hydrokinetic system. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1998;86(2):220-223. doi:10.1016/ s1079-2104(98)90128-7.

Carrieri TC, de Freitas PM, Navarro RS, Eduardo Cde P, Mori M. Adhesion of composite luting cement to Er: YAG-laser-treated dentin. Lasers Med Sci. 2007;22(3):165-170. doi:10.1007/s10103-006-0433-7.

  • Abstract Viewed: 1145 times
  • PDF Downloaded: 295 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Make a Submission

Make a Submission

Information

  • For Readers
  • For Authors
  • For Librarians

Developed By

Open Journal Systems
  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

Iranian Medical Laser Association 

                                        

 

This journal is distributed under the terms of CC BY-NC 3.0.
Design and publishing by SBMU journals. All credits and honors to PKP for their OJS. 

Powered by OJSPlus