Shahid Beheshti University of Medical Sciences
  • Register
  • Login

Journal of Lasers in Medical Sciences

  • Home
  • Issues
    • Current Issue
    • Archives
  • Journal Info
    • About the Journal
    • Editorial Team
    • Indexing/Abstracting
    • Contact Us
  • Author Guideline
    • Submission Guide
    • Author Statement Form
    • Peer Review Process
    • Publication Fee
  • Ethics & Policies
    • Ethical Requirements
    • Authorship Rules
    • Withdrawal Regulations
    • Retraction Considerations
    • Privacy Statement
    • Licensing
    • Copyright Terms
  • Reviewer Guideline
  • New Submission
Advanced Search
  1. Home
  2. Archives
  3. Vol. 14 (2023): Continues Volume
  4. Original Article

Vol. 14 (2023)

Bahman 2023

The Efficacy of Long-Pulsed, 1064-nm Nd:YAG Laser Versus Aluminum Chloride 20% Solution in the Treatment of Axillary Hyperhidrosis Long-pulsed, 1064-nm Nd:YAG laser versus aluminum chloride 20% solution in axillary hyperhidrosis

  • Mehdi Gheisari
  • Reza M Robati
  • Zahra Hasanzadeh Tabatabai
  • Tara Barat

Journal of Lasers in Medical Sciences, Vol. 14 (2023), 29 Bahman 2023 , Page e71
Published: 2023-12-29

  • View Article
  • Download
  • Cite
  • References
  • Statastics
  • Share

Abstract

Introduction: Hyperhidrosis (HH) refers to uncontrollable excessive sweating that has a significant negative impact on the quality of life. The aim of this study was to compare the efficacy and safety of the long-pulsed, 1064-nm Nd: YAG laser and aluminum chloride (ALCL3) 20% solution in axillary HH treatment.
Methods: In this single-center, within-patient comparison clinical trial, 12 patients with axillary HH were treated monthly for 3 to 4 consecutive sessions with the long-pulsed, 1064-nm Nd:YAG laser system on one axilla, while the contralateral axilla was treated with ALCL3 20 % by the patient. Treatment response was evaluated by comparing the area of sweating at the end of each session and 6 months after treatment termination using the iodine starch test.
Results: Both treatments led to the reduction of HH from baseline with the mean area of sweating reduced from 109.3±36.6 to 38.3±19.8 and from 92.5±31.6 to 35.6±17.1 in laser- and ALCL3-treated axilla respectively (Both P<0.001). In the 6-month follow-up, the area of sweating was 60.6±29.2 in the laser-treated armpit and 78.3±23.6 in the ALCL3-treated side, which were 45% and 14.4% lower compared to the baseline respectively. Adverse events were temporary, and none caused each of the treatments to be discontinued.
Conclusion: The long-pulsed, 1064-nm Nd: YAG laser with hair reduction setting can stand as a potential therapeutic option for axillary HH since it is as effective as ALCL3. The therapeutic effect is superior in the long term for the laser; nevertheless, the beneficial effect of both treatments may lessen the following treatment cessation.

Keywords:
  • Nd:YAG laser; Aluminum chloride; Axillary hyperhidrosis
  • PDF

How to Cite

Gheisari, M., Robati, R. M., Tabatabaei , Z., & Barat, T. (2023). The Efficacy of Long-Pulsed, 1064-nm Nd:YAG Laser Versus Aluminum Chloride 20% Solution in the Treatment of Axillary Hyperhidrosis: Long-pulsed, 1064-nm Nd:YAG laser versus aluminum chloride 20% solution in axillary hyperhidrosis. Journal of Lasers in Medical Sciences, 14, e71. Retrieved from https://journals.sbmu.ac.ir/jlms/article/view/43925
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX

References

See the References list in the PDF file.

  • Abstract Viewed: 657 times
  • PDF Downloaded: 307 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Make a Submission

Make a Submission

Information

  • For Readers
  • For Authors
  • For Librarians

Developed By

Open Journal Systems
  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

Iranian Medical Laser Association 

                                        

 

This journal is distributed under the terms of CC BY-NC 4.0.
Design and publishing by SBMU journals. All credits and honors to PKP for their OJS. 

Powered by OJSPlus