Diode Laser Irradiation Effects on Miniscrew Stability and IL-1β and TGF-β1 Levels: A Split-Mouth Randomized Controlled Clinical Trial Diode Laser Effects on Miniscrew Stability
Journal of Lasers in Medical Sciences,
Vol. 14 (2023),
29 Bahman 2023
,
Page e3
Abstract
Introduction: This study aimed to assess the effect of low-level laser therapy (LLLT) on miniscrew stability and concentrations of interleukin-1β (IL-1β) and transforming growth factor-beta (TGF-β1) in peri-miniscrew crevicular fluid in the course of orthodontic treatment.
Methods: This randomized split-mouth double-blind clinical trial evaluated 18 patients requiring anterior retraction along with maximum anchorage. Miniscrews were placed between the maxillary second premolar and first molar. A diode laser was irradiated with a 980-nm wavelength and 100-mW output power in continuous-wave mode at four-time points: T0 (1 hour after miniscrew placement), T1 (1 week later), T2 (at 1 month) and T3 (at 3 months) in one quadrant of the maxilla (laser group). The other quadrant of the maxilla underwent the pseudo-application of the laser (control group). The primary stability of mini-screws was measured by Periotest M and reported as Periotest value (PTV). Also, at each time point, samples were collected from the peri-miniscrew crevicular fluid one hour after laser irradiation to assess the concentration of IL-1β and TGF-β1.
Results: The mean PTV (inverse of the stability) was smaller in the laser group compared with the control group at all time points; this difference was significant at T2 and T3. The mean concentration of IL-1β in the laser group was lower than that in the control group at all time points, and this difference was significantly remarkable at T0 and T3. The mean concentration of TGF-β1 in the laser group was lower than that in the control group at T0, T1, and T3; however, the difference was not statistically significant.
Conclusions: The current results supported the efficacy of LLLT in increasing the miniscrew stability and decreasing the level of IL-1β pro-inflammatory cytokine
- Miniscrew stability; Low-level laser therapy; Interleukin-1β; Transforming growth factor-β1
How to Cite
References
1.Cope JB. Temporary anchorage devices in orthodontics: a paradigm shift. Semin Orthod. 2005;11(1):3-9. doi: 10.1053/j.sodo.2004.11.002.
2. Papageorgiou SN, Zogakis IP, Papadopoulos MA. Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis. Am J Orthod Dentofacial Orthop. 2012;142(5):577-95.e7. doi: 10.1016/j.ajodo.2012.05.016.
3. Kaur A, Kharbanda OP, Kapoor P, Kalyanasundaram D. A review of biomarkers in peri-miniscrew implant crevicular fluid (PMICF). Prog Orthod. 2017;18(1):42. doi: 10.1186/s40510-017-0195-8.
4. Zhang S, Choi Y, Li W, Shi D, Tang P, Yang L, et al. The effects of cortical bone thickness and miniscrew implant root proximity on the success rate of miniscrew implant: a retrospective study. Orthod Craniofac Res. 2022;25(3):342-50. doi: 10.1111/ocr.12538.
5. Yanaguizawa MS, Suzuki SS, Martinez EF, Suzuki H, Pelegrin MC, Garcez AS. Effects of low-level laser therapy in orthodontic patients on immediate inflammatory response after mini-implants insertion: a preliminary report. Photomed Laser Surg. 2017;35(1):57-63. doi: 10.1089/pho.2015.3959.
6. Aoki A, Mizutani K, Schwarz F, Sculean A, Yukna RA, Takasaki AA, et al. Periodontal and peri implant wound healing following laser therapy. Periodontol 2000. 2015;68(1):217-69. doi: 10.1111/prd.12080.
7. Abohabib AM, Fayed MM, Labib AH. Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial. J Orthod. 2018;45(3):149-56. doi:10.1080/14653125.2018.1481710.
8. Hemaid S, Saafan A, Hosny M, Wimmer G. Enhancement of Healing of periodontal intrabony defects using 810 nm diode laser and different advanced treatment modalities: a blind experimental study. Open Access Maced J Med Sci. 2019;7(11):1847-53. doi: 10.3889/oamjms.2019.484.
9. Elavarasu S, Naveen D, Thangavelu A. Lasers in periodontics. J Pharm Bioallied Sci. 2012;4(Suppl 2):S260-3. doi: 10.4103/0975-7406.100245.
10. de Oliveira Silva TS, Lima LM, Machado JI, Carvalho CM, de Moura CD. Influence of low-level laser on dental implant sites: a literature review. Dent Press Implantol. 2014;8(3):86-94. doi: 10.14436/2237-650X.8.3.086-094.oar.
11. Osman A, Abdel Moneim A, El Harouni N, Shokry M. Long-term evaluation of the effect of low-level laser therapy on orthodontic miniscrew stability and peri-implant gingival condition: a randomized clinical trial. J World Fed Orthod. 2017;6(3):109-14. doi: 10.1016/j.ejwf.2017.08.005.
12. Pinto MR, dos Santos RL, Pithon MM, de Souza Araújo MT, Braga JP, Nojima LI. Influence of low-intensity laser therapy on the stability of orthodontic mini-implants: a study in rabbits. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;115(2):e26-30. doi: 10.1016/j.oooo.2011.09.036.
13. Melsen B, Costa A. Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res. 2000;3(1):23-8. doi: 10.1034/j.1600-0544.2000.030105.x.
14. Yassaei S, Aghili H, Tavakol Afshari J, Bagherpour A, Eslami F. Effects of diode laser (980 nm) on orthodontic tooth movement and interleukin 6 levels in gingival crevicular fluid in female subjects. Lasers Med Sci. 2016;31(9):1751-9. doi: 10.1007/s10103-016-2045-1.
15. Ekizer A, Türker G, Uysal T, Güray E, Taşdemir Z. Light emitting diode mediated photobiomodulation therapy improves orthodontic tooth movement and miniscrew stability: a randomized controlled clinical trial. Lasers Surg Med. 2016;48(10):936-43. doi: 10.1002/lsm.225.
16. Olivé J, Aparicio C. Periotest method as a measure of osseointegrated oral implant stability. Int J Oral Maxillofac Implants. 1990;5(4):390-400.
17. Desmettre TJ, Soulie-Begu S, Devoisselle JM, Mordon SR. Diode laser-induced thermal damage evaluation on the retina with a liposome dye system. Lasers Surg Med. 1999;24(1):61-8. doi: 10.1002/(sici)1096-9101(1999)24:1 < 61::aid-lsm10 > 3.0.co;2-g.
18. Yassaei S, Zandi H, Aghili H, Rafiei E, Mosayebi N. Evaluation of the effect of two types of laser on the growth of Streptococcus mutans. Laser Ther. 2018;27(2):119-23. doi: 10.5978/islsm.18-OR-11.
19. Romanos GE, Everts H, Nentwig GH. Alterations of the implant surface after CO2- or Nd: YAG-laser irradiation: a SEM examination. J Oral Laser Appl. 2001;1(1):29-33.
20. Garcez AS, Suzuki SS, Martinez EF, Iemini MG, Suzuki H. Effects of low-intensity laser therapy over mini-implants success rate in pigs. Lasers Med Sci. 2015;30(2):727-32. doi: 10.1007/s10103-013-1367-5.
21. Goymen M, Isman E, Taner L, Kurkcu M. Histomorphometric evaluation of the effects of various diode lasers and force levels on orthodontic mini screw stability. Photomed Laser Surg. 2015;33(1):29-34. doi: 10.1089/pho.2014.3833.
22. Miura K, Motoyoshi M, Inaba M, Iwai H, Karasawa Y, Shimizu N. A preliminary study of the effects of low-intensity pulsed ultrasound exposure on the stability of orthodontic miniscrews in growing rats. Eur J Orthod. 2014;36(4):419-24. doi: 10.1093/ejo/cjt066.
23. Omasa S, Motoyoshi M, Arai Y, Ejima K, Shimizu N. Low-level laser therapy enhances the stability of orthodontic mini-implants via bone formation related to BMP-2 expression in a rat model. Photomed Laser Surg. 2012;30(5):255-61. doi: 10.1089/pho.2011.3157.
24. Veltri M, Balleri B, Goracci C, Giorgetti R, Balleri P, Ferrari M. Soft bone primary stability of 3 different miniscrews for orthodontic anchorage: a resonance frequency investigation. Am J Orthod Dentofacial Orthop. 2009;135(5):642-8. doi: 10.1016/j.ajodo.2007.05.025.
25. Sørensen LK, Havemose-Poulsen A, Bendtzen K, Holmstrup P. Aggressive periodontitis and chronic arthritis: blood mononuclear cell gene expression and plasma protein levels of cytokines and cytokine inhibitors. J Periodontol. 2009;80(2):282-9. doi: 10.1902/jop.2009.080347.
26. Bastos MF, Lima JA, Vieira PM, Mestnik MJ, Faveri M, Duarte PM. TNF-alpha and IL-4 levels in generalized aggressive periodontitis subjects. Oral Dis. 2009;15(1):82-7. doi: 10.1111/j.1601-0825.2008.01491.x.
27. Uysal T, Ekizer A, Akcay H, Etoz O, Guray E. Resonance frequency analysis of orthodontic miniscrews subjected to light-emitting diode photobiomodulation therapy. Eur J Orthod.2012;34(1):44-51. doi: 10.1093/ejo/cjq166.
- Abstract Viewed: 447 times
- PDF Downloaded: 518 times