SBMU Journals
  • New Submission
  • Register
  • Login
  • English
    • 简体中文

Archives of Academic Emergency Medicine

  • Home
  • About
    • Editorial Team
    • Journal Statistics
    • Journal Metrics and Rankings
    • Contact
  • Issues
    • Current
    • Archives
  • Announcements
  • Indexing/Abstracting
  • For authors
    • New Submission
    • Author guidelines
    • Article processing charge (APC)
    • FAQ
  • For Reviewers
  • Policies
    • Focus and Scope
    • Publication Frequency
    • Peer review process
    • Article withdrawal
    • Open Access Policy
    • Editorial Independence
    • Preprint Policy
    • Archiving Policy
    • Plagiarism Policy
    • Peer Review Policy
  • Ethics
    • Ethical requirements
    • Authorship conflicts
    • Malpractice statements
    • Copyright Notice
    • Intellectual properties
    • Privacy Statement
    • Artificial intelligence & Authorship
    • Retraction Cosiderations
Advanced Search
  1. Home
  2. Archives
  3. Vol. 14 No. 1 (2026): Continuous volume
  4. Original/Research Article

Vol. 14 No. 1 (2026)

October 2025

Diagnostic Accuracy of Serial Focused Assessment Sonography in Blunt Abdominal Trauma: A Systematic Review and Meta-Analysis

  • Apirut Hongsuwan
  • Amarit Tansawet
  • Suphakarn Techapongsatorn

Archives of Academic Emergency Medicine, Vol. 14 No. 1 (2026), 1 October 2025 , Page e64
https://doi.org/10.22037/aaem.v14i1.3162 Published: 2026-10-29

  • View Article
  • Download
  • Cite
  • References
  • Statastics
  • Share

Abstract

Introduction: A single Focused Assessment with Sonography for Trauma (FAST) examination has limited sensitivity in blunt abdominal trauma (BAT) because free-fluid detection is volume- and time-dependent. This systematic review and meta-analysis aimed to evaluate the pooled diagnostic accuracy of repeated or serial FAST in blunt abdominal trauma. Methods: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses for diagnostic test accuracy (PRISMA-DTA) and PRISMA 2020 statements, we searched databases for studies reporting the accuracy of serial FAST against a reference standard (abdominal computed tomography (CT) scan, surgery, diagnostic peritoneal aspiration, or clinical follow-up) in BAT patients. Two-by-two data were pooled with bivariate random-effects models (Reitsma; Nyaga generalized linear mixed model (GLMM)); sensitivity and specificity were also pooled separately (DerSimonian–Laird). Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 and certainty of evidence was evaluated using Grading of Recommendations Assessment, Development and Evaluation (GRADE). Results: Eleven studies (>2,800 patients) were included; seven with a complete 2×2 table entered the primary model, two provided sensitivity only, and two were not comparable. Pooled sensitivity was 0.85 (95% confidence interval (CI): 0.77–0.90) and specificity 0.98 (95% CI: 0.92–0.99); positive and negative likelihood ratios were 41.0 (95% CI: 10.7–156.7) and 0.15 (95% CI: 0.10–0.24), and the diagnostic odds ratio 265 (95% CI: 67–1046). Adding the sensitivity-only studies raised sensitivity to 0.87 (95% CI: 0.80–0.93). Specificity was higher in adults than children (0.99 vs 0.90; p<0.001); sensitivity did not differ (p = 0.52). Sensitivity rose with the timing of the repeat scan, from 0.64 at 4 hours to 0.88 at 12 hours. Certainty of evidence was Low. Conclusions: Serial FAST has high specificity and moderate, time-dependent sensitivity, with a large positive likelihood ratio. Because the certainty of the evidence is low, these estimates should be interpreted cautiously. A positive result markedly increases the probability of intra-abdominal injury, whereas a negative result does not exclude it and requires structured observation or definitive imaging.

Keywords:
  • Focused Assessment with Sonography for Trauma
  • Abdominal Injuries
  • Sensitivity and Specificity
  • Meta-Analysis
  • pdf

How to Cite

1.
Hongsuwan A, Tansawet A, Techapongsatorn S. Diagnostic Accuracy of Serial Focused Assessment Sonography in Blunt Abdominal Trauma: A Systematic Review and Meta-Analysis. Arch Acad Emerg Med [Internet]. 2026 Oct. 29 [cited 2026 Nov. 7];14(1):e64. Available from: https://journals.sbmu.ac.ir/aaem/index.php/AAEM/article/view/3162
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX

References

1. American College of Surgeons Committee on Trauma. Ad-vanced Trauma Life Support (ATLS) Course Manual. 11th ed. Chicago, IL: American College of Surgeons;2025. p. 288–303.

2. Rozycki GS, Ochsner MG, Jaffin JH, Champion HR. Prospec-tive evaluation of surgeons' use of ultrasound in the evalua-tion of trauma patients. J Trauma. 1993;34(4):516–26.

3. Stengel D, Leisterer J, Ferrada P, Ekkernkamp A, Mutze S, Hoenning A. Point-of-care ultrasonography for diagnosing thoracoabdominal injuries in patients with blunt trauma. Cochrane Database Syst Rev. 2018;12(12): CD012669. doi:10.1002/14651858.CD012669.pub2.

4. Netherton S, Milenkovic V, Taylor M, Davis PJ. Diagnostic accuracy of eFAST in the trauma patient: a systematic review and meta-analysis. CJEM. 2019;21(6):727–38.

5. Von Kuenssberg Jehle D, Stiller G, Wagner D. Sensitivity in detecting free intraperitoneal fluid with the pelvic views of the FAST exam. Am J Emerg Med. 2003;21(6):476–8.

6. Blackbourne LH, Soffer D, McKenney M, Amortegui J, Schulman CI, Crookes B, et al. Secondary ultrasound exami-nation increases the sensitivity of the FAST exam in blunt trauma. J Trauma. 2004;57(5):934–8.

7. Rajabzadeh Kanafi A, Giti M, Gharavi MH, Alizadeh A, Pourghorban R, Shekarchi B. Diagnostic accuracy of second-ary ultrasound exam in blunt abdominal trauma. Iran J Ra-diol. 2014;11(3):e21010.

8. Yazici MM, Yavasi O, Celik A, Altuntas G, Altuntas M, Bilir O, et al. The role of repeated extended FAST in patients with stable blunt thoracoabdominal trauma. Ulus Travma Acil Cerrahi Derg. 2023;29(5):553–9.

9. Mohammadi A, Ghasemi-Rad M. Evaluation of gastrointes-tinal injury in blunt abdominal trauma "FAST is not reliable": the role of repeated ultrasonography. World J Emerg Surg. 2012;7(1):2.

10. Poletti PA, Kinkel K, Vermeulen B, Irmay F, Unger PF, Terrier F. Blunt abdominal trauma: should US be used to de-tect both free fluid and organ injuries? Radiology. 2003;227(1):95–103.

11. Kakran A, Singh R, Chaudhary P, Chaudhary AK, Saquib Ali M. Sensitivity and specificity of serial focused assessment with sonography in trauma (FAST) in patients with blunt abdominal trauma. Cureus. 2025;17(9):e92103.

12. Bahrami-Motlagh H, Hajijoo F, Mirghorbani M, Saleva-tiPour B, Haghighimorad M. Test characteristics of focused assessment with sonography for trauma (FAST), repeated FAST, and clinical exam in prediction of intra-abdominal in-jury in children with blunt trauma. Pediatr Surg Int. 2020;36(10):1227–34.

13. Nti BK, Benzoni N, Starr R, Hays M, Vish D, End B, et al. Serial Trauma Abdominal Ultrasound in Children (STAUNCH): a pilot study. Pediatr Emerg Care. 2024;40(9):623–6.

14. Quinn R, Hsu J, Pang T. Can we trust them? FAST and DPA in assessing unstable patients following blunt ab-dominal trauma. Surgeries. 2024;5(3):674–81.

15. Lingawi SS, Buckley AR. Focused abdominal US in pa-tients with trauma. Radiology. 2000;217(2):426–9.

16. Kendall JL, Faragher J, Hewitt GJ, Burcham G, Haukoos JS. Emergency department ultrasound is not a sensitive detector of solid organ injury. West J Emerg Med. 2009;10(1):1–5.

17. McInnes MDF, Moher D, Thombs BD, McGrath TA, Bos-suyt PM. Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies: the PRISMA-DTA statement. JAMA. 2018;319(4):388–96.

18. Whiting PF, Rutjes AWS, Westwood ME, Mallett S, Deeks JJ. QUADAS-2: a revised tool for the quality assessment of di-agnostic accuracy studies. Ann Intern Med. 2011;155(8):529–36.

19. Reitsma JB, Glas AS, Rutjes AWS, Scholten RJPM, Bossuyt PM, Zwinderman AH. Bivariate analysis of sensitivity and specificity produces informative summary measures in diag-nostic reviews. J Clin Epidemiol. 2005;58(10):982–90.

20. Rutter CM, Gatsonis CA. A hierarchical regression ap-proach to meta-analysis of diagnostic test accuracy evalua-tions. Stat Med. 2001;20(19):2865–84.

21. Nyaga VN, Arbyn M. Metadta: a Stata command for meta-analysis and meta-regression of diagnostic test accuracy data – a tutorial. Arch Public Health. 2022;80(1):95.

22. Nyaga VN, Arbyn M, Aerts M. Metaprop: a Stata com-mand to perform meta-analysis of binomial data. Arch Public Health. 2014;72(1):39.

23. Guyatt GH, Oxman AD, Vist GE, Kunz R, Falck-Ytter Y, Alonso-Coello P, et al. GRADE: an emerging consensus on rat-ing quality of evidence and strength of recommendations. BMJ. 2008;336(7650):924–6.

24. Schünemann HJ, Mustafa RA, Brozek J, Steingart KR, Leeflang M, Murad MH, et al. GRADE guidelines:21 part 1. Study design, risk of bias, and indirectness in rating the cer-tainty across a body of evidence for test accuracy. J Clin Epi-demiol. 2020;122:129–41.

25. Schünemann HJ, Mustafa RA, Brozek J, Steingart KR, Leeflang M, Murad MH, et al. GRADE guidelines:21 part 2. Test accuracy: inconsistency, imprecision, publication bias, and other domains for rating the certainty of evidence and presenting it in evidence profiles and summary of findings tables. J Clin Epidemiol. 2020;122:142–52.

26. Holmes JF, Kelley KM, Wootton-Gorges SL, Utter GH, Abramson LP, Rose JS, et al. Effect of Abdominal Ultrasound on Clinical Care, Outcomes, and Resource Use Among Chil-dren With Blunt Torso Trauma: A Randomized Clinical Trial. JAMA. 2017;317(22):2290–6.

  • Abstract Viewed: 37 times
  • pdf Downloaded: 26 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Make a Submission

Make a Submission

SJR

SCImago Journal & Country Rank

COPE

Current Issue

  • Atom logo
  • RSS2 logo
  • RSS1 logo

Information

  • For Readers
  • For Authors
  • For Librarians
  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

This journal is distributed under the terms of CC BY-NC 3.0. Design and publishing by SBMU journals. All credits and honors to PKP for their OJS. 

 Sitemap | ISSN-ONLINE: 2645-4904

Support Contact: ma.saghaei63@gmail.com

With the goal of net zero carbon emissions, this journal is published only in electronic format.

Powered by OJSPlus