Background and Aim: Microbiological culture of dialysis water is a routine safety measure. In, Khorramabad laboratories perform these cultures on Muller Hinton Agar (MHA) at 35–378C for 48 h, not on the Reasoner’s 2A agar (R2A agar) at 17–238ºC for 7 days recommended by international standards, the objective of the present study was the comparison of the efficiency of R2A and MHA media in the counting of heterotrophic bacteria in the samples of water collected in dialysis centers from 2 hospitals in Khorramabad, from September to November 2019.
Methods: A total of 165 samples of treated water in dialysis centers were collected aseptically and then transported in ice‑packs to the Department of Medical Microbiology of the Lorestan University of Medical Sciences and the pour plate technique was carried out for the enumerating of heterotrophic bacteria. Finally, bacterial colonies were counted after incubation at 34±2ºC for 48 hours on MHA and 25ºC for 1 week on R2A.
Results: Results showed heterotrophic bacterial counts in R2A were greater than those in MHA in 89% of the samples, so enumeration of heterotrophic bacteria should be carried out in R2A agar associated with longer incubation times, because of the greater sensitivity. The proportion of water samples yielding colony counts ≥200 CFU/mL by R2A -7d was significantly different from the proportion by MHA-48h (p<0.001).
Conclusion: The results proposed using R2A agar combined with relative low culture temperature (20-25°C), and an extended incubation time (7-10 days) is more efficient. However, as the spectrum of bacterial contamination is not similar for dialysis centers and countries, many studies using different media and culture parameters are required to confirm this.
*Corresponding Author: Faranak Rezaei; Email: Rezaei.f@lums.ac.ir
Please cite this article as: Pouladi I, Delfani S, Hadian B, Soroush S, Anbari K, Rezaei F. Comparison of Reasoner’s 2A Agar and Muller Hinton Agar Media for Microbiological Monitoring of Dialysis Water. Arch Med Lab Sci. 2020;6:1-5 (e10). https://doi.org/10.22037/amls.v6.32905
- Dialysis Water
- Heterotrophic Bacteria
- Pour Plate
- Reasoner’s 2A Agar
- R2A agar
How to Cite
References
Kashiwagi T, Sato K, Kawakami S, Kiyomoto M, Takei H, Suzuki T, et al. The performance evaluation of endotoxin retentive filters in haemodialysis. Journal of Nippon Medical School. 2011;78(4):214-23.
WARD RA. Worldwide water standards for hemodialysis. Hemodialysis International. 2007;11:S18-S25.
Bolasco P, Contu A, Meloni P, Vacca D, Murtas S. The evolution of technological strategies in the prevention of dialysis water pollution: sixteen years’ experience. Blood purification. 2012;34(3-4):238-45.
Hoenich NA, Ronco C, Levin R. The importance of water quality and haemodialysis fluid composition. Blood purification. 2006;24(1):11-8.
Pontoriero G, Pozzoni P, Andrulli S, Locatelli F. The quality of dialysis water. Nephrology Dialysis Transplantation. 2003;18(suppl_7):vii21-vii5.
Archibald LK, Khoi NN, Jarvis WR, Reller LB, Cam PD, Thu TA, et al. Pyrogenic reactions in hemodialysis patients, Hanoi, Vietnam. Infection Control & Hospital Epidemiology. 2006;27(4):424-6.
Oie S, Kamiya A, Yoneda I, Uchiyama K, Tsuchida M, Takai K, et al. Microbial contamination of dialysate and its prevention in haemodialysis units. Journal of Hospital Infection. 2003;54(2):115-9.
Varo SD, Martins CHG, Cardoso MJdO, Sartori FG, Montanari LB, Pires-Gonçalves RH. Isolamento de fungos filamentosos em água utilizada em uma unidade de hemodiálise. Revista da Sociedade Brasileira de Medicina Tropical. 2007;40(3):326-31.
Reasoner DJ. Heterotrophic plate count methodology in the United States. International journal of food microbiology. 2004;92(3):307-15.
Allen MJ, Edberg SC, Reasoner DJ. Heterotrophic plate count bacteria—what is their significance in drinking water?. International journal of food microbiology. 2004;92(3):265-74.
Vorbeck-Meister I, Sommer R, Vorbeck F, Hörl WH. Quality of water used for haemodialysis: bacteriological and chemical parameters. Nephrology, dialysis, transplantation: official publication of the European Dialysis and Transplant Association-European Renal Association. 1999;14(3):666-75.
Revision USPCCo, editor US pharmacopeia & national formulary: United States Pharmacopeial Convention, Inc. 2008
Reasoner DJ, Geldreich E. A new medium for the enumeration and subculture of bacteria from potable water. Applied and environmental microbiology. 1985;49(1):1-7.
Federation WE, Association APH. Standard methods for the examination of water and wastewater. American Public Health Association (APHA): Washington, DC, USA. 2005.
Carter J, Rice E, Buchberger S, Lee Y. Relationships between levels of heterotrophic bacteria and water quality parameters in a drinking water distribution system. Water Research. 2000;34(5):1495-502.
Pérez‐García R, Rodríguez‐Benítez POC. Why and how to monitor bacterial contamination of dialysate. Nephrology Dialysis Transplantation. 2000;15(6):760-4.
Organization WH. WHO Expert Committee on Specifications for Pharmaceutical Preparations: fifty-fourth report. 2020.
Okunola Y, Ayodele O, Akinwusi P, Gbadegesin B, Oluyombo R. Haemodialysis practice in a resource–limited setting in the tropics. Ghana Medical Journal. 2013;47(1):4-9.
Bamgboye EL. Hemodialysis: management problems in developing countries, with Nigeria as a surrogate. Kidney International. 2003;63:S93-S5.
Uhl W, Schaule G. Establishment of HPC (R2A) for regrowth control in non-chlorinated distribution systems. International journal of food microbiology. 2004;92(3):317-25.
Pratices ASaR. AAMI/DS‑IRD62 Water Treatment Equipment for Haemodialysis Applications. Arlington, VA, USA:. Association for the Advancement of Medical Instrumentation. 2000:2-32.
Group EBPGW. European Best Practice Guidelines for haemodialysis (Part 1). Section IV. Dialysis fluid purity. Nephrol Dial Transplant. 2002;17(suppl 7):S45-S6.
Kaneko M, Tominaga Y, Sakamoto K, Shikata H. Hemodialysis vascular access infection caused by Methylobacterium radiotolerans: The first confirmed case in Japan. Journal of Infection and Chemotherapy. 2020;26(1):107-9.
Bugno A, Almodóvar AAB, Pereira TC. Enumeration of heterotrophic bacteria in water for dialysis: comparison of the efficiency of Reasoner'2 agar and plate count agar. Brazilian Journal of Microbiology. 2010;41(1):15-8.
Abualhasan M, Basim A, Sofan S, Al-Atrash M. Quality of water used in Palestinian hemodialysis centers. Public health. 2018;165:136-41.
Al‐Naseri SK, Mahdi ZM, Hashim MF. Quality of water in hemodialysis centers in B aghdad, I raq. Hemodialysis International. 2013;17(4):517-22.
- Abstract Viewed: 228 times
- PDF Downloaded: 91 times