Iranian Center for Endodontic Research
  • Login
  • Register

Iranian Endodontic Journal

  • Register
  • Home
  • About the journal
  • Issues
    • Current
    • Archives
  • For Authors/Reviewers
    • Submissions
    • Author Guidelines
    • Ethics Policy
    • Editorial & Peer Review Policy
    • Privacy Statement
    • Reviewers Information
  • Indexing/Abstracting
  • Editorial Team
  • Announcements
  • Contact Us
  • Congress Proceedings
Advanced Search
  1. Home
  2. Archives
  3. Vol. 1 No. 2 (2006): SUMMER 2006
  4. Original Article

Vol. 1 No. 2 (2006)

July 2006

Reproducible X-Ray Projection Geometry in Endodontic Practice

  • Zohre Ghalamkarpour
  • Hengameh Ashraf
  • Mohammad Ali Mozayani
  • Ramin Yazdani

Iranian Endodontic Journal, Vol. 1 No. 2 (2006), 1 July 2006 , Page 53-56
https://doi.org/10.22037/iej.v1i2.411 Published: 2008-12-07

  • View Article
  • Download
  • Cite
  • Statastics
  • Share

Abstract

INTRODUCTION: Clinical application of radiography in endodontic practice is affected by reproducibility in the orientation of the x-ray source, image receptor and object. The inability of dentists to locate intra oral films or sensors in appropriate positions in different cases can cause complications in the performance of endodontic therapy. Commercially available film holder (endoray) and conventional imaging methods seem to be insufficient and difficult to perform. The purpose of this investigation was to develop a novel and easily performed device for endodontic radiography and to asses its reproducibility and accuracy in vitro. MATERIALS AND METHODS: The present work surveys and evaluates the design steps of a newly constructed film holder with modified bite block and a beam guiding device, in an attempt to perform a diagnostic study. References wires and balls were attached on the film holder and to the alveolar crest of maxillary molar region inserted in the conventional phantom for measuring the projection errors relative to the film holder and repositioning .One hundred and twenty radiographs of a conventional phantom were taken by one of the authors and by two dental students using the novel device and Endoray. RESULTS: The %95 CI for precision of radiologist and one of the students was less than 8 (7.313 ± 0.1989) .The %95 CI for precision of the other student was less than 12 (10.941 ± 0.4217). There was no significant difference (p= 0.679), regarding the interoperator precision, between radiologist and first student. There was significant difference between second student and the others (p<0.05). No significant difference was noted between the radiographs achieved by the Endoray and new device. CONCLUSION: The novel device appears to be a potential means of obtaining reproducible radiographs in endodontic practice. Further research is needed however, to study in vivo aspects, reproducibility and accuracy.

Keywords:
  • Endodontics
  • Reproducible
  • X-Ray
  • PDF

How to Cite

1.
Ghalamkarpour Z, Ashraf H, Mozayani MA, Yazdani R. Reproducible X-Ray Projection Geometry in Endodontic Practice. Iran Endod J [Internet]. 2008 Dec. 7 [cited 2025 May 12];1(2):53-6. Available from: https://journals.sbmu.ac.ir/iej/article/view/411
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX
  • Abstract Viewed: 279 times
  • PDF Downloaded: 225 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Make a Submission

Make a Submission

Information

  • For Readers
  • For Authors
  • For Librarians

Developed By

Open Journal Systems

Indexing/Abstracting

This journal is indexed in:

  • PubMed
  • Europe PMC
  • Scopus
  • SCImago
  • MIAR
  • CINAHL
  • CAS (Chemical Abstracts)
  • Dimensions
  • DOAJ
  • EBSCO
  • FATCAT
  • Google Scholar
  • IMEMR (Index Medicus for the WHO Eastern Mediterranean Region)
  • Index Copernicus
  • ISC (Islamic World Science Citation Center)
  • Magiran
  • ROAD
  • SID (Scientific Information Database) 
  • SUDOC
  • UC Santa Barbara University
  • WIKIDATA
  • ZDB
    • This journal is Member of: COPE; ICMJ

Current Issue

  • Atom logo
  • RSS2 logo
  • RSS1 logo

Browse

  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

   Iranian Endodontic Journal is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Powered by OJSPlus