Influence of Rotation Speed of Mtwo Files on Root Canal Instrumentation Time with Different Canal Curvatures
Iranian Endodontic Journal,
Vol. 16 No. 1 (2021),
1 January 2021
,
Page 38-42
https://doi.org/10.22037/iej.v16i1.24773
Abstract
Introduction: The aim of this study was to analyze the effect of rotation speed on the instrumentation time of root canals with different curvatures using Mtwo NiTi rotary instruments. Methods and Materials: Forty root canals were selected and divided into 2 groups, according to the angle of curvature (group A>30°, group B<30°). Both groups were divided into 2 subgroups (n=10), according to the rotational speed used for root canal instrumentation (150 rpm: group A1 and B1; 250 rpm: group A2 and B2). The total instrumentation time and the total number of instrumentation cycles (NCI) required to complete root canal preparation were registered for each canal. The mean and standard deviation were then calculated. Data were then statistically analyzed using two-way ANOVA and interaction effect P-values (P<0.05). Results: During root canal instrumentation, there were no file fractures. Total instrumentation time of the low speed groups A1 (150 rpm) and B1 (150 rpm) were significantly higher (P<0.05) than that of the high speed groups, A2 (250 rpm) and B2 (250 rpm); however, there was no statistically significant difference in terms of NCI between the different groups (P>0.05). Statistical difference was not found between the different angles of curvature, group A1 vs B1 and A2 vs B2 in terms of total instrumentation time (P>0.05) and NCI (P>0.05). Conclusions: This ex-vivo study showed that canal preparation with Mtwo rotary files could be completed safely with an increase of the instrumentation time at low rotational speed independently of the root canal curvature.
- Mtwo Rotary System; Nickel-titanium; Root Canal Preparation; Root Canal Therapy
How to Cite
References
Plotino G, Grande NM, Cordaro M, Testarelli L, Gambarini G. A review of cyclic fatigue testing of nickel-titanium rotary instruments. J Endod. 2006;35:1469-76.
Pruett JP, Clement DJ, Carnes DL. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod. 1997;23:77–85.
Pedullà E, Lo Savio F, Boninelli S, Plotino G, Grande NM, La Rosa G et al. Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining. J Endod. 2016;42:156-9.
Pedullà E, Lo Savio F, Boninelli S, Plotino G, Grande NM, Rapisarda E et al. Influence of cyclic torsional preloading on cyclic fatigue resistance of nickel-titanium instruments. Int Endod J. 2015;48:1043-50.
Sattapan B, Palamara JE, Messer HH. Torque during canal instrumentation using rotary nickel-titanium files. J Endo. 2000;26:156-60.
Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod. 2004;30:559-67.
Parashos P, Messer HH. Rotary NiTi instrument fracture and its consequences. J Endod. 2006;32:1031-1043.
Al-Sudani D, Grande NM, Plotino G, Pompa G, Di Carlo S, Testarelli L et al. Cyclic fatigue of nickel-titanium rotary instruments in a double (S-shaped) simulated curvature. J Endod. 2012;38:987-9.
Grande NM, Plotino G, Pecci R, Bedini R, Malagnino VA, Somma F. Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems. Int Endod J. 2006;39:755-63.
Pedullà E, Plotino G, Grande NM, Scibilia M, Pappalardo A, Malagnino VA et al. Influence of rotational speed on the cyclic fatigue of Mtwo instruments. Int Endod J. 2014;47:514-519.
Kitchens GG, Liewehr FR, Moon PC. The effect of operational speed on the fracture of nickel-titanium rotary instruments. J Endod. 2007;33:52-4.
Gao Y, Shotton V, Wilkinson K, Phillips G, Johnson WB. Effect of raw material and rotational speed on the cyclic fatigue of ProFile Vortex rotary instruments. J Endod. 2010;36:1205-9.
Gabel WP, Hoen M, Steiman HR, Pink FE, Dietz R. Effect of rotational speed on nickel-titanium file distortion. J Endod. 1999;25:752-4.
Martin B, Zelada G, Varela P, Bahillo JG, Magan F, Ahn S et al. Factors influencing the fracture of nickel- titanium rotary instruments. Int Endod J. 2003;36:262-6.
Inan U, Aydin C, Demirkaya K. Cyclic fatigue resistance of new and used Mtwo rotary nickel-titanium instruments in two different radii of curvature. Aust Endod J. 2011;37:105-8.
Timothy AS. Instruments for Cleaning and Shaping. In: Ingle JI, Bakland LK, Baumgartner JG editors. Ingle’s ENDODONTICS 6th ed. Hamilton, Ontario: BC Decker Inc; 2008:850-858.
Parashos P, Gordon I, Messer HH. Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use. J Endod. 2004;30:722-725.
Madarati AA, Watts DC, Qualtrough AJE. Factors contributing to the separation of endodontic files. Br Dent J. 2008;204:241-245.
Mandel E, Adib-Yazdi M, Benhamou LM, Lachkar T, Mesgouez C, Sobel M. Rotary Ni-Ti profile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage. Int Endod J. 1999;32:436-443.
Marending M, Lutz F, Barbakow F. Scanning electron microscope appearances of Lightspeed instruments used clinically: a pilot study. Int Endod J. 1998;31:57-62.
Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol. 1971;32:271-5.
Plotino G, Grande NM, Sorci E, Malagnino VA, Somma F. A comparison of cyclic fatigue between used and new Mtwo Ni–Ti rotary instruments. Int Endod J. 2006;39:716-23.
McGuigan MB, Louca C, Duncan HF. The impact of fractured endodontic instruments on treatment outcome. Br Dent J. 2013;214:285-9.
McGuigan MB, Louca C, Duncan HF. Clinical decision-making after endodontic instrument fracture. Br Dent J. 2013;214:395-400.
Knight, C.M. Evaluating a skills centre: the acquisition of psychomotor skills in nursing – a review of the literature. Nurse Educ Today. 1998;18:441-7.
Plotino G, Al-Sudani D, Pulino S, Grande NM, Marcoli PA, Pizzi S et al. Cyclic fatigue resistance of Mtwo NiTi rotary instruments used by experienced and novice operators--an in vivo and in vitro study. Med Sci Monit. 2012;18:41-5.
Inan U, Gonulol N. Deformation and fracture of Mtwo rotary nickel-titanium instruments after clinical use. J Endod. 2009;35:1396-9.
Plotino G, Grande NM, Sorci E, Malagnino VA, Somma F. Influence of a brushing working motion on the fatigue life of NiTi rotary instruments. Int Endod J. 2007;40:45-51.
Bürklein S, Hinschitza K, Dammaschke T, Schäfer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J. 2012;45:449-61.
Yared G, Sleiman P. Failure of ProFile instruments used with air, high torque control, and low torque control motors. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002;93:92-6.
Zelada G, Varela P , Martín B, et al. The effect of rotational speed and the curvature of root canals on the breakage of rotary endodontic instruments. J Endod. 2002;28:540-2.
Di Giuseppe I, Di Giuseppe D, Malagnino VA, Silla EP, Somma F. Conditioning of root canal anatomy on static and dynamics of nickel-titanium rotary instruments. Giornale Italiano di Endodonzia. 2015;29:58-64.
Alapati SB, Brantley WA, Svec TA, Powers JM, Mitchell JC. Scanning electron microscope observations of new and used nickel-titanium rotary files. J Endod. 2003;29:667-9.
- Abstract Viewed: 310 times
- PDF Downloaded: 195 times