Iranian Center for Endodontic Research
  • Login
  • Register

Iranian Endodontic Journal

  • Register
  • Home
  • About the journal
  • Issues
    • Current
    • Archives
  • For Authors/Reviewers
    • Submissions
    • Author Guidelines
    • Ethics Policy
    • Editorial & Peer Review Policy
    • Privacy Statement
    • Reviewers Information
  • Indexing/Abstracting
  • Editorial Team
  • Announcements
  • Contact Us
  • Congress Proceedings
Advanced Search
  1. Home
  2. Archives
  3. Vol. 12 No. 2 (2017): Spring 2017
  4. Original Article

Vol. 12 No. 2 (2017)

Farvardin 2017

Effect of Field Of View on Detection of External Root Resorption in Cone-Beam Computed Tomography

  • Yaser Safi
  • Sahar Ghaedsharaf
  • Alireza Aziz
  • Sepanta Hosseinpour
  • Hamed Mortazavi

Iranian Endodontic Journal, Vol. 12 No. 2 (2017), 28 Farvardin 2017 , Page 179-184
https://doi.org/10.22037/iej.v12i2.13242 Published: 2017-03-28

  • View Article
  • Download
  • Cite
  • Statastics
  • Share

Abstract

Introduction: Conventional methods for diagnosis of external root resorption (ERR) are based on clinical findings and x-ray observations which are not appropriate for early diagnosis. The present study assessed the effect of different sizes and field of views (FOVs) in the diagnosis of simulated external root resorption by cone-beam computed tomography (CBCT). Methods and Materials: In this diagnostic in vitro trial, 100 human extracted mandibular central incisors were collected and marked in 3 apical, middle and coronal areas. Cavities with different sizes were created in buccal and lingual surfaces of each area. Following this procedure, CBCT images were taken in 2 different 6 × 6 cm and 12 × 8 cm FOVs with the same voxel size of 0.2 mm. Absence or presence of cavities in CBCT images were assigned by 3 radiologists and compared with gold standard results which were obtained by measurement of the size of cavities using a digital caliper. Sensitivity and specificity values, positive predictive value (PPV) and negative predictive value (NPV), AZ value and Kappa values were calculated and reported. Results: Amounts of sensitivity in 6 × 6 cm FOV with voxel size of 0.2 mm for small, medium and large cavities were 95.93%, 96.03% and 97.1%, respectively. Amounts of sensitivity in 12 × 8cm FOV with the same voxel size for small, medium and large cavities were noted as 94.4%, 96.03% and 98.5%, respectively. However, specificity in FOV of 6 × 6 cm and FOV of 12 × 8 cm was calculated as 93.03% and 90.83%, respectively. Conclusion: Both used FOVs show nearly same performances in the case of detection of ERR; therefore, smaller FOV should be preferably used for detection of ERR in order to decrease the amount of imposed radiation dose given to patients.

Keywords: Cone-Beam Computed Tomography; External Root Resorption; Field of View

  • PDF

How to Cite

1.
Safi Y, Ghaedsharaf S, Aziz A, Hosseinpour S, Mortazavi H. Effect of Field Of View on Detection of External Root Resorption in Cone-Beam Computed Tomography. Iran Endod J [Internet]. 2017 Mar. 28 [cited 2026 Jul. 8];12(2):179-84. Available from: https://journals.sbmu.ac.ir/iej/article/view/13242
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX
  • Abstract Viewed: 307 times
  • PDF Downloaded: 361 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Make a Submission

Make a Submission

Information

  • For Readers
  • For Authors
  • For Librarians

Developed By

Open Journal Systems

Indexing/Abstracting

This journal is indexed in:

  • PubMed
  • Europe PMC
  • Scopus
  • SCImago
  • MIAR
  • CINAHL
  • CAS (Chemical Abstracts)
  • Dimensions
  • DOAJ
  • EBSCO
  • FATCAT
  • Google Scholar
  • IMEMR (Index Medicus for the WHO Eastern Mediterranean Region)
  • Index Copernicus
  • ISC (Islamic World Science Citation Center)
  • Magiran
  • ROAD
  • SID (Scientific Information Database) 
  • SUDOC
  • UC Santa Barbara University
  • WIKIDATA
  • ZDB
    • This journal is Member of: COPE; ICMJ

Current Issue

  • Atom logo
  • RSS2 logo
  • RSS1 logo

Browse

  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

   Iranian Endodontic Journal is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Powered by OJSPlus