Long-Term Anterior Segment Biometric Changes after Posterior Chamber Phakic Intraocular Lens Implantation: Conventional Versus Aquaport Implantable Collamer Lens
Journal of Ophthalmic and Optometric Sciences,
Vol. 9 No. 3 (2025),
22 Tir 2025
,
Page 19-29
https://doi.org/10.22037/joos.v9i3.51238
Abstract
Purpose: To compare biometric changes after implantation of posterior chamber phakic collamer lenses (PCLs) in conventional and Aquaport ICL models.
Patients and Methods: Records of myopic patients who underwent ICL implantation between March 2012 and April 2015 were reviewed. Demographics, manifest and cycloplegic refraction, BCVA, and preoperative IOP were documented. All patients underwent ultrasonic biomicroscopy to determine sulcus-to-sulcus distance and angle parameters under dim illumination (STS, Quantel Biomedical, France), along with topography and keratometric measurements. Patients were recalled postoperatively for repeat ultrasonic biomicroscopy under identical settings. Keratometric values were also obtained using the Galilei Dual Scheimpflug Tomography Analyzer (Ziemer, Switzerland).
Results: Fifty-eight eyes of 30 myopic patients were included; 28 eyes of 15 patients were assigned to the V4b group and 30 eyes of 15 patients to the V4c group. Mean follow-up time was 27.7 ± 9.3 months in the V4b group and 26.6 ± 8.8 months in the V4c group. No significant differences in postoperative refraction or intraocular pressure were observed between groups at 1 and 3 months. All preoperative biometric parameters changed after surgery in both groups. Nasal angle parameters (TIA-nasal and AOD500-N) differed significantly between V4b and V4c lenses, while other biometric indices and lens densitometry showed no significant differences.
Conclusion: The central-hole design of the V4c ICL appears as effective as peripheral iridotomy in V4b lenses in preventing deterioration of anterior-segment biometric parameters and may promote a more uniform aqueous humor outflow at the anterior chamber angle.
- Phakic Intraocular Lenses
- Myopia
- Anterior Chamber
- Biometry
- Intraocular Pressure
- Tomography
- Optical Coherence
How to Cite
References
1. Güell JL, Morral M, Kook D, Kohnen T. Phakic intraocular lenses part 1: historical overview, current models, selection criteria, and surgical techniques. J Cataract Refract Surg. 2010;36(11):1976-93.
2. Zaldivar R, Ricur G, Oscherow S. The phakic intraocular lens implant: in-depth focus on posterior chamber phakic IOLs. Curr Opin Ophthalmol. 2000;11(1):22-34.
3. Fernandes P, González-Méijome JM, Madrid-Costa D, Ferrer-Blasco T, Jorge J, Montés-Micó R. Implantable collamer posterior chamber intraocular lenses: a review of potential complications. J Refract Surg. 2011;27(10):765-76.
4. Kawamorita T, Uozato H, Shimizu K. Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforation. Graefes Arch Clin Exp Ophthalmol. 2012;250(6):935-9.
5. Fujisawa K, Shimizu K, Uga S, Suzuki M, Nagano K, Murakami Y, et al. Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye. Graefes Arch Clin Exp Ophthalmol. 2007;245(1):114-22.
6. Chun YS, Park IK, Lee HI, Lee JH, Kim JC. Iris and trabecular meshwork pigment changes after posterior chamber phakic intraocular lens implantation. J Cataract Refract Surg. 2006;32(9):1452-8.
7. McCaughey MV, Mifflin T, Fenzl CR, Goldsmith J, Moshirfar M. Pseudophacomorphic Glaucoma along with Pupillary Block after Visian™ Implantable Collamer Lens Implantation for High Myopia. Open J Ophthalmol. 2014;4(4):107-11.
8. Fernández-Vigo JI, Macarro-Merino A, Fernández-Vigo C, Fernández-Vigo JÁ, Martínez-de-la-Casa JM, Fernández-Pérez C, et al. Effects of Implantable Collamer Lens V4c Placement on Iridocorneal Angle Measurements by Fourier-Domain Optical Coherence Tomography. Am J Ophthalmol. 2016;162:43-52.
9. Mansouri K, Burgener ND, Bagnoud M, Shaarawy T. A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology following laser iridotomy in European eyes. Eye (Lond). 2009;23(11):2046-51.
10. Gazzard G, Friedman DS, Devereux JG, Chew P, Seah SK. A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology after laser iridotomy in Asian eyes. Ophthalmology. 2003;110(3):630-8.
11. Lee H, Kang SY, Seo KY, Chung B, Choi JY, Kim KS, et al. Dynamic vaulting changes in V4c versus V4 posterior chamber phakic lenses under differing lighting conditions. Am J Ophthalmol. 2014;158(6):1199-204.
12. Lee H, Kang DS, Ha BJ, Choi M, Kim EK, Seo KY, et al. Effect of Accommodation on Vaulting and Movement of Posterior Chamber Phakic Lenses in Eyes With Implantable Collamer Lenses. Am J Ophthalmol. 2015 Oct;160(4):710-6.
13. Lee DH, Choi SH, Chung ES, Chung TY. Correlation between preoperative biometry and posterior chamber phakic Visian Implantable Collamer Lens vaulting. Ophthalmology. 2012;119(2):272-7.
14. Alfonso JF, Fernández-Vega L, Lisa C, Fernandes P, González-Meijome J, Montés-Micó R. Long-term evaluation of the central vault after phakic Collamer® lens (ICL) implantation using OCT. Graefes Arch Clin Exp Ophthalmol. 2012;250(12):1807-12.
15. Higueras-Esteban A, Ortiz-Gomariz A, Gutiérrez-Ortega R, Villa-Collar C, Abad-Montes JP, Fernandes P, et al. Intraocular pressure after implantation of the Visian Implantable Collamer Lens With CentraFLOW without iridotomy. Am J Ophthalmol. 2013;156(4):800-5.
16. Almalki S, Abubaker A, Alsabaani NA, Edward DP. Causes of elevated intraocular pressure following implantation of phakic intraocular lenses for myopia. Int Ophthalmol. 2016;36(2):259-65.
17. Huseynova T, Ozaki S, Ishizuka T, Mita M, Tomita M. Comparative study of 2 types of implantable collamer lenses, 1 with and 1 without a central artificial hole. Am J Ophthalmol. 2014;157(6):1136-43.
- Abstract Viewed: 24 times
- pdf Downloaded: 23 times