Intra Corneal Cleft Secondary to Ocular Massage after Ahmed Valve Surgery
Journal of Ophthalmic and Optometric Sciences,
Vol. 2 No. 1 (2018),
1 Dey 2018
,
Page 44-46
https://doi.org/10.22037/joos.v2i1.28555
Abstract
Purpose: To report a case of acute intra corneal cleft in a patient undergoing ocular massage following Ahmed valve implantation.
Case Report: Acute intra corneal cleft occurred in a patient following the use of ocular massage to reduce IOP and bleb formation after Ahmed glaucoma valve insertion. Previous history of the patient was Fuchs heterochromic iridocyclitis without any report of trauma to his eye or any other ophthalmic disorders. The slit lamp examination revealed huge localized corneal bulla formation with a diameter of 3 mm in the superior mid peripheral corneal region in the right eye just after ocular massage, which persisted in the 6 months of follow up.
Conclusion: Digital ocular massage might cause the occurrence of intra corneal cleft. Although this might be a very rare complication, we should consider it as an adverse effect of ocular massage.
Keywords: Glaucoma; Cornea; Cleft; Massage.
How to Cite
References
Smith M, Geffen N, Alasbali T, Buys YM, Trope GE. Digital ocular massage for hypertensive phase after Ahmed valve surgery. J Glaucoma. 2010;19(1):11-4.
Kane H, Gaasterland DE, Monsour M. Response of Filtered Eyes to Digital Ocular Pressure. Ophthalmology. 1997;104(2):202-6.
Ali M, Akhtar F. Ocular digital massage for the management of post-trabeculectomy under filtering blebs. J Coll Physicians Surg Pak. 2011;21(11):676-9.
Fakhraie G, Vahedian Z. Post Filtering Surgery Globe Massage-induced Keratoconus in an Eye with Iridocorneal Endothelial Syndrome: A Case Report and Literature Brief Review. Journal of ophthalmic & vision research. 2016;11(3):319-22.
Baldassare R, Brunette I, Desjardins D, Amyot M. Corneal ectasia secondary to excessive ocular massage following trabeculectomy with 5-fluorouracil. Canadian journal of ophthalmology Journal canadien d'ophtalmologie. 1996;31(5):252-4.
Honda Y, ichiro Kawano S, Negi A, Koizumi K. Pressure profile of ophthalmic surgical procedures: an experimental study on the rabbit eye. Ophthalmic Surgery, Lasers and Imaging Retina. 1982;13(5):387-91.
Miller GR, Kurstin J. Ruptured filtering bleb after ocular massage. Archives of Ophthalmology. 1966;76(3):363.
Segrest DR, Ellis PP. Iris incarceration associated with digital ocular massage. Ophthalmic Surgery, Lasers and Imaging Retina. 1981;12(5):349-51.