Effect of Different Heparin Volumes on Blood Gas Analysis
Journal of Pediatric Nephrology,
Vol. 7 No. 3 (2019),
16 November 2019
,
Page 1-4
https://doi.org/10.22037/jpn.v7i3.26775
Abstract
Abstract
Background and Aim: Blood gas analysis is an important laboratory test for diagnosis and treatment of a variety of medical conditions in emergency rooms. Inaccurate sample collection is one of the reasons for errors in blood gas analysis. This study was conducted to evaluate different volumes of heparin in syringes and the effect of sample dilution on blood gas analysis as one of the main factors affecting the results of blood gas analysis.
Methods: One hundred children (4 months to 12 years) who presented to Loghman Hakim Hospital, Tehran, Iran, were enrolled in this study. Two samples were taken from each patient. For the first sample, the syringes were filled with heparin sodium and then emptied completely to achieve a very thin layer anticoagulant coating. For the second sample, the syringes were filled with 0.1 mL of liquid heparin sodium 5000 U/mL (5%). The blood gas parameters including pH, PO2, PCO2, HCO3 and BE (base excess) were measured. Data were analyzed using SPSS version 18.
Results: All parameter had lower levels in second samples (0.1 mL heparin 5%) except for PO2 compared to the first samples (P < 0.001).
Conclusion: This study found that a small amount of heparin in the syringe changed the result of blood gas analysis.
Keywords: Blood Gas Analysis; Heparin; pH; PCO2; HCO3.
- Blood Gas Analysis
- Heparin
- PH
- PCO2
- HCO3.
How to Cite
References
Verma AK, Roach P. The interpretation of arterial blood gases. Aust Prescr. 2010;33(4):124-9.
Gonzalez AL, Waddell LS. Blood gas analyzers. Topics in companion animal medicine. 2016;31(1):27-34.
Batra P, Dwivedi AK, Thakur N. Bedside ABG, electrolytes, lactate and procalcitonin in emergency pediatrics. International journal of critical illness and injury science. 2014;4(3):247-52.
Singh V, Khatana S, Gupta P. Blood gas analysis for bedside diagnosis. National journal of maxillofacial surgery. 2013;4(2).
Taghizadieh A, Pouraghaei M, Moharamzadeh P, Ala A, Rahmani F, Sofiani KB. Comparison of end-tidal carbon dioxide and arterial blood bicarbonate levels in patients with metabolic acidosis referred to emergency medicine. Journal of cardiovascular and thoracic research. 2016;8(3):98.
Madati PJ, Bachur R. Development of an emergency department triage tool to predict acidosis among children with gastroenteritis. Pediatric emergency care. 2008;24(12):822-30.
Dukić L, Milevoj Kopčinović L, Dorotić A, Baršić I. Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Biochemia medica: Biochemia medica. 2016;26(3):318-36.
Mahto HL, Sasikumar S. Blood gas sampling-Pre-analytical issues. Indian Journal of Respiratory Care. 2017;6(1):758.
Nigam PK. Correct Blood Sampling for Blood Gas Analysis. Journal of clinical and diagnostic research: JCDR. 2016;10(10):BL01.
Organization WH. WHO guidelines on drawing blood: best practices in phlebotomy. 2010.
Baird G. Preanalytical considerations in blood gas analysis. Biochemia medica. 2013;23(1):19-27.
Bleul U, Götz E. Effect of syringe type, storage temperature and time delay on venous blood gas values in newborn calves. Comparative Clinical Pathology. 2015;24(1):117-25.
Mohammadhoseini E, Safavi E, Seifi S, Seifirad S, Firoozbakhsh S, Peiman S. Effect of sample storage temperature and time delay on blood gases, bicarbonate and pH in human arterial blood samples. Iranian Red Crescent Medical Journal. 2015;17(3).
Albert TJ, Swenson ER. Circumstances When Arterial Blood Gas Analysis Can Lead Us Astray. Respiratory Care; 2016.
Kume T, Sisman AR, Solak A, Tuglu B, Cinkooglu B, Coker C. The effects of different syringe volume, needle size and sample volume on blood gas analysis in syringes washed with heparin. Biochemia medica. 2012;22(2):189-201.
Sandler P, Goldstein L. The effect of different forms of heparin on point-of-care blood gas analysis. South African Medical Journal. 2018;108(3):224-9.
Chhapola V, Kumar S, Goyal P, Sharma R. Use of liquid heparin for blood gas sampling in pediatric intensive care unit: A comparative study of effects of varying volumes of heparin on blood gas parameters. Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine. 2013;17(6):350-4.
Knowles TP, Mullin RA, Hunter JA, Douce HF. Effects of syringe material, sample storage time, and temperature on blood gases and oxygen saturation in arterialized human blood samples. Respiratory care. 2006;51(7):732-6.
Lockwood W. Blood Gas Analysis. 2016. WWW.RN.ORG.
Shirani F, Salehi R, Naini AE, Azizkhani R, Gholamrezaei A. The effects of hypotension on differences between the results of simultaneous venous and arterial blood gas analysis. Journal of research in medical sciences: the official journal of Isfahan University of Medical Sciences. 2011;16(2):188.
HEPARIN SODIUM- heparin sodium injection, solution [updated 04.06.2015. Available from: http://dailymed.nlm.nih.gov/dailymed/drugInfo.cfm?setid=efcdb321-832b-4554-8049-dbbb33b48334.
Nassiri AA, Hakemi MS, Soulati M, Marashian M, Rahbar K, Azizi F. Effects of heparin and dalteparin on oxidative stress during hemodialysis in patients with end-stage renal disease. Iranian journal of kidney diseases. 2009;3(3):162-7.
Liu J, Zhou L, He Z, Gao N, Shang F, Xu J, et al. Structural analysis and biological activity of a highly regular glycosaminoglycan from Achatina fulica. Carbohydrate polymers. 2018;181:433-41.
Higgins C. The use of heparin in preparing samples for blood-gas analysis. Medical Laboratory Observer. 2007;39(10):16.
Chhapola V, Kumar S, Goyal P, Sharma R. Use of liquid heparin for blood gas sampling in pediatric intensive care unit: A comparative study of effects of varying volumes of heparin on blood gas parameters. Indian journal of critical care medicine: peer-reviewed, official publication of Indian Society of Critical Care Medicine. 2013;17(6):350.
Lockwood W. Blood Gas Analysis. 2018. WWW.RN.ORG.
- Abstract Viewed: 402 times