The Effect of Intraocular Pressure on Corneal Topographic Findings of Donor Cornea
Journal of Ophthalmic and Optometric Sciences,
Vol. 1 No. 5 (2017),
23 September 2017
,
Page 12-16
https://doi.org/10.22037/joos.v1i5.28009
Abstract
Purpose: To evaluate the effect of intraocular pressure on topographic findings of donor corneas.
Materials and Methods: In the present study 37 intact enucleated globes were included. Desirable intraocular pressure was provided by fluid flowing into the globe using a needle inserted via the optic nerve connected to a balanced salt serum bottle. The Sim K and corneal astigmatism in different IOPs (0, 10, 20, 30, 40 and 50 mmHg) were measured using a topography cone (Zeiss-Humphery System, Atlas Version 10.1).
Results: Out of 37 globes studied, 26 globes (70.3 %) were from male and 11 globes (29.7 %) were from female donors. Donors were aged 25 to 45 years at time of death with the mean age of 37 years. The mean Sim K was not significantly different in different IOP levels (0 to 50 mmHg). The mean corneal astigmatism had a significant relation with IOP (P < 0.001) and decreased (IOP 0 mmHg to IOP 30 mmHg) then increased (IOP 30 mmHg to IOP 50 mmHg) when the IOP was changed. The minimum astigmatism was detected at IOP 30 mmHg (1.56 D) and the maximum was detected at IOP 0 mmHg (2.76 ± 1.73).
Conclusion: The mean Sim K of donor cornea does not significantly change in different IOP levels of enucleated globe, while the corneal astigmatism changes significantly. It seems that keratometric readings from donor cornea might be used without caution about the IOP in enucleated globe.
Key words: Eye globe; IOP; Sim K; Astigmatism.
How to Cite
References
Geerards AJ, Hassmann E, Beekhuis WH, Remeyer L, van Rij G, Rijneveld WJ. Triple procedure; analysis of outcome, refraction, and intraocular lens power calculation. Br J Ophthalmol. 1997;81(9):774–7.
Hjortdal JO, Ehlers N, Erdmann L. Topography of corneal grafts before and after penetrating keratoplasty. Acta Ophthalmol Scand. 1997;75(6): 645-8.
Lim-Bon-Siong R, Williams JM, Samapunphong S, Chuck RS, Pepose JS. Screening of myopic photorefractive keratectomy in eye bank eyes by computerized videokeratography. Arch Ophthalmol. 1998;116(5):617-23.
Katz HR, Forster RK. Intraocular lens calculation in combined penetrating keratoplasty, cataract extraction and intraocular lens implantation. Ophthalmology. 1985;92(9):1203-7.
Vicha I, Vlková E, Hlinomazová Z, Loukotová V, Horácková M, Nĕmec J, et al. Calculation of diopter value of the IOL in simultaneous cataract surgery and perforating keratoplasty. Cesk Slov Oftalmol. 2007;63(1):36-41. (Article in Czech)
Lim-Bon-Siong R, Williams JM, Samapunphong S, Chuck RS, Pepose JS. Screening of myopic photorefractive keratectomy in eye bank eyes by computerized videokeratography. Arch Ophthalmol. 1998;116(5):617-23.
Hjortdal JO, Böhm A, Kohlhaas M, Olsen H, Lerche R, Ehlers N, et al. Mechanical stability of the cornea after radial keratotomy and photorefractive keratectomy. J Refract Surg. 1996;12(4):459-66.
Stoiber J, Ruckhofer J, Hitzl W, Grabner G. Evaluation of donor tissue with a new videokeratoscope: the Keratron Scout. Cornea. 2001;20(8):859-63.
Hjortdal JO. Extensibility of the normo-hydrated human cornea. Acta Ophthalmol Scand. 1995;73(1):12-7.
Dave AS, McCulley JP. Demonstration of feasibility of application of a portable keratometer to cadaveric donor corneas. Cornea. 1994;13(5):379-82.
Brenman K, Tahi H, Manns F, Duchesne B, Parel JM, Lacombe E. Assessment of changes in corneal shape as a function of intraocular pressure: A pilot study. Proceedings of SPIE - The International Society for Optical Engineering. 2000;3908.
- Abstract Viewed: 89 times
- PDF Downloaded: 53 times