An in-house indirect immunofluorescence test for ensuring that the cell bank is contamination free
Archives of Medical Laboratory Sciences,
Vol. 1 No. 3 (2015),
20 December 2015
https://doi.org/10.22037/amls.v1i3.11512
Abstract
Background: Cross-contamination between cells is a usual mistake at cell culture laboratories and cell banks worldwide. MRC5 diploid cell and Rk-13, Vero and Hela continuous cell lines are used in different stages of human viral vaccines propagation at Razi Vaccine and Serum Research Institute of Iran. However diploid and continuous cells are propagated at separated cell culture laboratory and continuous cells can contaminate MRC5 diploid cells. Therefore, a sensitive test is needed. World Health Organization recommends few molecular and cellular techniques to cell characterization.
Materials and Methods: The present study was therefore designed to set up an indirect immunofluorescence (IIF) test as follows: Polyclonal anti-MRC5 cell and anti-rabbit antibodies were prepared in rabbit and goat, respectability. Anti-rabbit IgG was purified using protein G affinity chromatography, conjugated to fluorescein isothiocyanate (FITC), and then further purified to remove unbound FITC using Sephadex G 25 chromatography. Using double immunodiffusion assay, purification of homemade anti-rabbit IgG was asssayed by observation of a single arch.
Results: The titer of homemade FITC conjugated goat anti rabbit IgG was measured 1/16 vs 1/8 of commercial type. Fluorescein/protein molar ratio of local made fluorescein goat anti-rabbit IgG was measured 3.44 and its protein concentration and FITC concentration were determined 1.198 mg/ml and 0.01 mg/ml, respectively.
Conclusion: Moreover, homemade IIF test showed 100% intra-laboratory reproducibility. Purity of three batches of MRC5 working seed cell was verified using in- house IIF test and no contamination to continuous cell lines was found .
- MRC-5
- cross-contamination
- indirect immunofluorescence technique
- Quality Control Test
- human viral vaccine
How to Cite
References
Jacobs JP, Jones CM, Baille JP. Characteristics of a human diploid cell designated MRC-5. Nature. 1970;227(5254):168-70.
WHO technical report series 200 (1960). 2005;927:135-7.
Capes-Davis A, Theodosopoulos G, Atkin I, Drexler HG, Kohara A, MacLeod RA, et al. Check your cultures! A list of cross-contaminated or misidentified cell lines. International journal of cancer Journal international du cancer. 2010;127(1):1-8.
Masters J. False cell lines. International journal of cancer Journal international du cancer. 2002;99(1):154.
Johnen G, Rozynek P, von der Gathen Y, Bryk O, Zdrenka R, Johannes C, et al. Cross-contamination of a UROtsa stock with T24 cells--molecular comparison of different cell lines and stocks. PloS one. 2013;8(5):e64139.
Buehring GC, Eby EA, Eby MJ. Cell line cross-contamination: how aware are Mammalian cell culturists of the problem and how to monitor it? In vitro cellular & developmental biology Animal. 2004;40(7):211-5.
Rojas A, Gonzalez I, Figueroa H. Cell line cross-contamination in biomedical research: a call to prevent unawareness. Acta pharmacologica Sinica. 2008;29(7):877-80.
Krisna C. Duong-Ly SBG. Methods in Enzymology. USA: Elsevier Inc. 2014.
Wingfield P. Current Protocols in Protein Science: John Wiley & Sons, Inc. 1998.
Feltkamp TE. Conjugation of fluorescein isothiocyanate to antibodies. I. Experiments on the conditions of conjugation.Immunology. 1970;18(6):865-73.
Spectrum Application Note. Determining the most Effective Dialysis MWCO for Protein Purification.
Hornbeck P. Double-Immunodiffusion Assay for Detecting Specific Antibodies: John Wiley & Sons, Inc; 1991.
Johnstone A, Thorpe R. Immunochemistry in Practice. Third ed. USA: Blackwell Science Ltd; 1996.
Barallon R, Bauer SR, Butler J, Capes-Davis A, Dirks WG, Elmore E, et al. Recommendation of short tandem repeat profiling for authenticating human cell lines, stem cells, and tissues. In vitro cellular & developmental biology Animal. 2010;46(9):727-32.
Nakazawa M MM, Miyatake K. Immunoelectron Microscopy, Methods in Molecular Biology. 2010.
Odell ID, Cook D. Immunofluorescence techniques. The Journal of investigative dermatology. 2013;133(1):e4.
Hanly WC, Artwohl JE, Bennett BT. Review of Polyclonal Antibody Production Procedures in Mammals and Poultry. ILAR journal / National Research Council, Institute of Laboratory Animal Resources. 1995;37(3):93-118.
Stills HF, Jr. Adjuvants and antibody production: dispelling the myths associated with Freund's complete and other adjuvants. ILAR journal / National Research Council, Institute of Laboratory Animal Resources. 2005;46(3):280-93.
Hay RY CJ, Macy ML. ATCC quality control methods for cell lines.1992.
Calculate dye:protein (F/P) molar ratios In: Inc. TFS, editor. TR003172011.
de Oliveira AP, de Castro MC, de Almeida AF, Souza Mde A, de Oliveira BC, Reis LC, et al. Comparison of flow cytometry and indirect immunofluorescence assay in the diagnosis and cure criterion after therapy of American tegumentary leishmaniasis by anti-live Leishmania (Viannia) braziliensis immunoglobulin G. Journal of immunological methods. 2013;387(1-2):245-53.
Reina J, Ballesteros F, Ruiz de Gopegui E, Munar M, Mari M. Comparison between indirect immunofluorescence assay and shell vial culture for detection of mumps virus from clinical samples. Journal of clinical microbiology. 2003;41(11):5186-7.
Buchwalow IB, Minin EA, Boecker W. A multicolor fluorescence immunostaining technique for simultaneous antigen targeting. Acta histochemica. 2005;107(2):143-8.
Bloemberg D, Quadrilatero J. Rapid determination of myosin heavy chain expression in rat, mouse, and human skeletal muscle using multicolor immunofluorescence analysis. PloS one. 2012;7(4):e35273.
Suzuki T, Tate G, Ikeda K, Mitsuya T. A novel multicolor immunofluorescence method using heat treatment. Acta medica Okayama. 2005;59(4):145-51.
Brouns I, Van Nassauw L, Van Genechten J, Majewski M, Scheuermann DW, Timmermans JP, et al. Triple immunofluorescence staining with antibodies raised in the same species to study the complex innervation pattern of intrapulmonary chemoreceptors. The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society. 2002;50(4):575-82.
Frisch J, Houchins JP, Grahek M, Schoephoerster J, Hagen J, Sweet J, et al. Novel multicolor immunofluorescence technique using primary antibodies raised in the same host species. Methods in molecular biology. 2011;717:233-44.
- Abstract Viewed: 504 times
- PDF Downloaded: 319 times